Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove Harness from Gas Valve
Remove connector X6a from PCB
Remove connector X6a from PCB
Measurement:
Test resistance of the wire. The Neutral splits in two at gas valve plug so must be tested on both.
The Gas Valve connector is numbered 1 to 5 from top to bottom.
3 & Live (Brown on X6a Plug).
then 1 & Neutral (Blue on X6a Plug).
and 4 & Neutral (Blue on X6a Plug).
Expect short circuit on all tests.
The Gas Valve connector is numbered 1 to 5 from top to bottom.
3 & Live (Brown on X6a Plug).
then 1 & Neutral (Blue on X6a Plug).
and 4 & Neutral (Blue on X6a Plug).
Expect short circuit on all tests.

Isolate as per TOPs P4
and refit as necessary