Set Appliance State:
Mains Power Off
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect plug connector (marked JP11) from PCB
Remove the microswitch from the top of the diverter valve
Remove the microswitch from the top of the diverter valve
Measurement:
Check resistance across connections C & D (Brown & Blue wires)
Expect short circuit.
Now depress the microswitch.
Expect open circuit.
Replace connector and microswitch after test.
Note: Care should be taken that probe tips do not touch each other when taking measurement as a false reading will be given.
Expect short circuit.
Now depress the microswitch.
Expect open circuit.
Replace connector and microswitch after test.
Note: Care should be taken that probe tips do not touch each other when taking measurement as a false reading will be given.

Isolate as per TOPs P4
and refit as necessary