Set Appliance State:

Turn Hot Water Tap On
DHW temperature control to maximum
CH temperature control to minimum
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Observation:

Run the hot tap and allow the boiler to heat for a short time.
Using temperature probes for the FGA (Flue Gas Analyser) measure the temperature on the primary flow pipe just above the over heat stat and return pipe just above the pump, there should be a temperature differential of between 14-18°C across the flow and return pipes.