4758129 RAVENHEAT LS80 WITH SINGLE COMBINED PCB
GLOBALLY REPLACED
RAVENHEAT LS80
G.C. NUMBER 47 581 2
DHW PUMP RUNS
REMOVE THE VENT PLUG FROM THE PUMP
DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)
LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.
DHW MODULATION
LOOSEN THE OUTLET TE
CH OPERATION
LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.
SYSTEM PRESSURE RISE
SELECTOR SWITCH TO HEATING AND HOT WATER POSITION
CH MODULATION
LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT.
GAS VALVE VARIATION
DURING THE PRODUCTIO
OVERHEAT INVESTIGATIONPUMP RUNS
SWITCH - MAIN
OVERHEAT INVESTIGATIONDHW PUMP RUNS
FUSE F1 (2A)
OVERHEAT INVESTIGATIONLOW WATER
SYSTEM PRESSURE
OVERHEAT INVESTIGATIONPUMP RUNS
SENSOR DHW
OVERHEAT INVESTIGATIONPUMP RUNS
SENSOR CH
OVERHEAT INVESTIGATIONDHW PUMP RUNS
FLOW SWITCH 3 WAY VALVE MICROSWITCH
BURNER PRESSURE LOW
GAS INLET PRESSURE
OVERHEAT INVESTIGATIONPUMP RUNS
SWITCH - SUMMER/WINTER
MOD SOL
GAS VALVE
OVERHEAT INVESTIGATIONNO HEATING
SENSOR CH
OVERHEAT INVESTIGATIONCH POT
CH POTENTIOMETER
OVERHEAT INVESTIGATIONLOW BURNER PRESS
SENSOR CH
OVERHEAT INVESTIGATIONBURNER PRESSURE LOW
SENSOR DHW
OVERHEAT INVESTIGATIONLOW BRUNER PRESS
DHW POTENTIOMETER
OVERHEAT INVESTIGATIONBURNER PRESSURE LOW
GAS INLET PRESSURE
OVERHEAT INVESTIGATIONMOD SOL
GAS VALVE
OVERHEAT INVESTIGATION
SECONDARY (DHW) HEAT EXCHANGER
OVERHEAT INVESTIGATION
HEAT EXCHANGER
FUSE INVESTIGATION
PUMP
FUSE INVESTIGATION - MODULATION SOLENOID
GAS VALVE
DHW PUMP RUNS
MAINS FUSE
DHW PUMP RUNS
FUSE F1 (2A)
DOES NOT LIGHT - SPARKING SEEN
ELECTRODE
DHW COOL RADS COOL
SENSOR CH
DHW RUNS HOT COLD
SENSOR CH
FUSE INVESTIGATION - MAIN SOLENOID
GAS VALVE
PUMP RUNS
DIVERTER VALVE 3 -WAY
NOT LIGHTING
GAS INLET PRESSURE
NOT LIGHTING
PCB
NOT LIGHTING
GAS VALVE
NOT LIGHTING
BURNER
DHW MODULATION
DHW POTENTIOMETER
BOILER UP TO TEMP, RADIATORS COLD
DIVERTER VALVE 3 -WAY
BOILER NOISY, KETTLING
DIVERTER VALVE 3 -WAY
EXP VESS
EXPANSION VESSEL
CH MODULATION
SENSOR CH
CH MODULATION
CH POTENTIOMETER
CH PUMP OVERRUNS
SENSOR CH
PUMP RUNS
SWITCH - MAIN
START
START
OH THERMOSTAT
THERMOSTAT- OVERHEAT
PUMP RUNS
SWITCH - SUMMER/WINTER
HEAT EX FLUE
HEAT EXCHANGER (FLUEWAYS)
GAS INLET PRES
GAS INLET PRESSURE
BAFFLES OUT
SEAL - COMBUSTION CHAMBER
AIR PRESSURE SWITCH TUBES
TUBES- PRESSURE SWITCH
DOESN'T CROSS LIGHT, PRESSURE ABSENT
GAS INLET PRESSURE
MOD SOL - NOT CROSS LIGHTING
GAS VALVE
FLUE VENTURI
FLUE VENTURI
FLUE
FLUE
DHW SENSOR (FULL DEMAND)
SENSOR DHW
DHW RUNS HOT AND COLD BURNER CYCLES ON AND OFF
DHW POTENTIOMETER
DHW CYCLING
PUMP
DHW TOO COOL RADIATORS COLD
SENSOR DHW
DHW MODULATION
SENSOR DHW
BOILER COLD, RADIATORS COLD
CH POTENTIOMETER
BOILER COLD, RADIATORS COLD
SENSOR CH
TOO HOT
CH POTENTIOMETER
TOO HOT
SENSOR CH
SHUTING OFF EARLY
SENSOR CH
SHUTING DOWN EARLY
CH POTENTIOMETER
NOT CROSS LIGHTING
INJECTOR- BURNER
NOT CROSS LIGHTING
BURNER
NOT CROSS LIGHTING
HEAT EXCHANGER (FLUEWAYS)
FAN IMPELLOR
FAN IMPELLOR
PUMP RUNS
SENSOR DHW
PUMP RUNS
SENSOR CH
DHW PUMP RUNS
FLOW SWITCH 3 WAY VALVE MICROSWITCH
LOW WATER
SYSTEM PRESSURE
SEQ OF OPS
SEQ OF OPS
GAS VALVE VARIATION
GAS VALVE VARIATION
DHW NOISY
DHW POTENTIOMETER
DHW NOISY
SENSOR DHW
DHW COOL
INJECTOR- BURNER
DV PUMP RUNS
PCB
LOW BURNER PRESS
SENSOR CH
BURNER PRESSURE LOW
SENSOR DHW
LOW BRUNER PRESS
DHW POTENTIOMETER
SPARKING
AIR PRESSURE SWITCH
SPARKING
ELECTRODE LEAD
SPARK GAP
ELECTRODE
SPARKING
SEAL - COMBUSTION CHAMBER
SPARKING
TUBES- PRESSURE SWITCH
SPARKING
FLUE VENTURI
SPARKING
FLUE
DHW FLOW RATE
DHW ISOLATING VALVE
NO HEATING
SENSOR CH
CH POT
CH POTENTIOMETER
FLOW SENSOR - FAN NOT RUNNING
SENSOR CH
FAN NOT RUNNING
SENSOR DHW
FAN NOT RUNNING
DHW POTENTIOMETER
LOW WATER NO FAN
SYSTEM PRESSURE
FAULT CODE
THERMOSTAT- OVERHEAT
OVERHEAT FAULT
PCB
OVERHEAT INVESTIGATION CH SENSOR
SENSOR CH
OVERHEAT INVESTIGATIONLOW WATER
PRESSURE SWITCH - LOW WATER
OVERHEAT INVESTIGATIONDHW SENSOR - PUMP RUNS
WIRING HARNESS
OVERHEAT INVESTIGATIONFLOW SENSOR - PUMP RUNS
WIRING HARNESS
OVERHEAT INVESTIGATIONPUMP RUNS
DIVERTER VALVE 3 -WAY
OVERHEAT INVESTIGATIONFLOW SENSOR - NO HEATING
WIRING HARNESS
OVERHEAT INVESTIGATIONLOW IGN PRESSURE
GAS VALVE ADJUSTMENT
FUSE INVESTIGATION
WIRING HARNESS
F1 FUSE FURTHER INVESTIGAITON
Z REDIRECT
MAINS FUSE FURTHER INVESTIGATION
Z REDIRECT
DHW TOO COOL RADIATORS HOT WITH NO CH DEMAND
DIVERTER VALVE 3 -WAY
FUSE INVESTIGATION
PCB FUSE INVESTIGATION
DHW PUMP RUNS - RESISTANCE OK
FLOW SWITCH 3 WAY VALVE MICROSWITCH
GAS INLET PRESSURE (FULL DEMAND)
GAS VALVE ADJUSTMENT
DHW FLOW RATE
DHW INLET FILTER
DHW TOO COOL RADIATORS COLD
HEAT EXCHANGER
BLOCKED
DIVERTER VALVE 3 -WAY
DHW PUMP RUNS
PUMP
CH MODULATION
PCB
CH PUMP OVERRUNS
PCB
FAN
FAN
BAFFLES OUT
ELECTRODE SENSING IGNITION
BAFFELS OUT
HARNESS FLAME SENSE
FLAME SENSE
PCB
AIR PRESSURE SWITCH
AIR PRESSURE SWITCH
NOT LIGHTING
INJECTOR- BURNER
DHW SENSOR - HOT WATER CYCLES
WIRING HARNESS
DHW CYCLING
SECONDARY (DHW) HEAT EXCHANGER
DHW SENSOR - DHW TOO COOL
WIRING HARNESS
DHW OPERATION NOISY
HEAT EXCHANGER
DHW MODULATION
PCB
DHW SENSOR - MOD
WIRING HARNESS
FLOW SENSOR - BOILER AND RADS COLD
WIRING HARNESS
BOILER TOO HOT
PCB
FLOW SENSOR - BOILER TOO HOT
WIRING HARNESS
BOILER NOISY, KETTLING
HEAT EXCHANGER
FLOW SENSOR - BOILER SHUT DOWN RADS COLD
WIRING HARNESS
NOT CROSS LIGHTING
FLUE
DHW SENSOR - PUMP RUNS
WIRING HARNESS
FLOW SENSOR - PUMP RUNS
WIRING HARNESS
LOW WATER
PRESSURE SWITCH - LOW WATER
FAN
WIRING HARNESS
LOW IGN PRESSURE
GAS VALVE ADJUSTMENT
DOESNT CROSS LIGHT
GAS VALVE ADJUSTMENT
DHW MODULATION
GAS VALVE ADJUSTMENT
CH MODULATION
GAS VALVE ADJUSTMENT
DHW NOISY
GAS VALVE ADJUSTMENT
DHW NOISY
PCB
DHW NOISY
WIRING HARNESS
DHW NOISY OPERATION KETTLES
SECONDARY (DHW) HEAT EXCHANGER
DHW TOO COOL RADIATORS COLD
DHW POTENTIOMETER
APS NO SPARKING
WIRING HARNESS
NO SPARKING
FAN
NO SPARK
PCB
FLOW SENSOR - NO HEATING
WIRING HARNESS
FLOW SENSOR - FAN NOT RUNNING
WIRING HARNESS
FAN NOT RUNNING DHW SENSOR
WIRING HARNESS
FAN NOT RUNNING
PCB
LOW WATER NO FAN
PRESSURE SWITCH - LOW WATER
SCALED
SECONDARY (DHW) HEAT EXCHANGER
TRIPPING EARLY - OVERHEAT INVESTIGATION
THERMOSTAT- OVERHEAT
NO FAULT FOUND
OVERHEAT
NO VOLTAGE PRESENT ON EITHER TEST
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
16V DC PRESENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
NO VOLTAGE PRESENT ON EITHER TEST
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
16 VDC PRESENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
DHW RUNS HOT AND COLD, BURNER CYCLES ON AND OFF
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO COOL, RADIATORS HOT
CHARACTERISTIC TEST FROM DHW OPERATION
DHW INLET FILTER BLOCKED
CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER
DHW TOO COOL, RADS COLD
CHARACTERISTIC TEST FROM DHW OPERATION
DHW NOISY OPERATION, KETTLES
CHARACTERISTIC TEST FROM DHW OPERATION
DIVERTER VALVE BLOCKED
CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER
BOILER NOISY, KETTLING
CHARACTERISTIC TEST FROM CH OPERATION
BOILER HOT BUT RADIATORS COLD
CHARACTERISTIC TEST FROM CH OPERATION
BOILER COLD, RADIATORS COLD
CHARACTERISTIC TEST FROM CH OPERATION
BURNER DOES NOT CROSS LIGHT CORRECTLY
CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)
LEAD OK BUT ELECTRODE IN POOR CONDITION
CHARACTERISTIC TEST FROM FLAME SENSE ELECTRODE AND LEAD
ELECTRODE OK BUT LEAD IN POOR CONDITION
CHARACTERISTIC TEST FROM FLAME SENSE ELECTRODE AND LEAD
BURNER LIGHTS BUT PRESSURE REMAINS LOW
CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)
BURNER DOES NOT LIGHT
CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)
BURNER CROSS LIGHTS BUT DOES NOT ESTABLISH / DROPS OUT / BAFFLES
CHARACTERISTIC TEST FROM DHW BURNER LIGHTS (PRESSURE TO MAXIMUM)
NO VOLTAGE PRESENT ON EITHER TEST
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
16 VDC PRESENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
NO VOLTAGE PRESENT ON EITHER TEST
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
16V DC PRESENT ON BOTH TESTS
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL PROGRAMMER
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS
OVERHEAT TRIPS BEFORE 85°C
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
FLOW TEMPERATURE ABOVE 90°C AND BOILER DOES NOT SHUT DOWN
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
20/09/2021 12:59:51 2109_1_50_1 23/09/2021 10:05:06
21/09/2021 07:01:41
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE PUMP
DISCONNECT CONNECTOR M4 FROM THE PCB
RESISTANCE FAN
DISCONNECT BROWN AND BLUE WIRES AT THE FAN
RESISTANCE MAINS FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
GAS INLET PRESSURE
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
DHW MODULATION VOLTAGE
SET FLOW RATE AT TAP TO APPROXIMATELY 5 L/MIN
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
PUMP VOLTAGE
USE INSULATION MAT AS REQUIRED
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
OVERHEAT THERMOSTAT RESISTANCE
REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT
ENSURE APPLIANCE IS COOL
AIR PRESSURE SWITCH RESISTANCE (NORMALLY OPEN)
REMOVE PLASTIC COVER FROM THE PCB
DISCONNECT THE CONNECTOR AT M3 FROM THE PCB
SUMMER/WINTER SWITCH RESISTANCE
REMOVE 1 CONNECTOR F
GAS INLET PRESSURE
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
FAN VOLTAGE FROM PCB
GAIN ACCESS TO PCB, USE INSULATION MAT AS REQUIRED
DHW MODULATION
LOOSEN THE OUTLET TE
DHW MODULATION VOLTAGE
SET FLOW RATE AT TAP TO APPROXIMATELY 5 L/MIN
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
BURNER INJECTOR CONDITION
REMOVE GAS RAIL FROM BOILER FOR INSPECTION
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
PRESSURE APS SWITCHING AT APS
REMOVE PLASTIC COVER FROM THE PCB
REMOVE AIR PRESSURE SWITCH CONNECTOR FROM M3 ON THE PCB
ELECTRODE LEAD INSPECTION
DISCONNECT ELECTRODE LEAD FROM PCB AND ELECTRODE
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
LOW WATER PRESSURE SWITCH MADE
LOCATE AND REMOVE CONNECTOR M12 FROM THE PCB
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
OVERHEAT THERMOSTAT RESISTANCE
REMOVE BOTH WIRES FROM THE OVERHEAT THERMOSTAT
ENSURE APPLIANCE IS COOL
PUMP VOLTAGE
USE INSULATION MAT AS REQUIRED
LOW WATER PRESSURE SWITCH MADE
LOCATE AND REMOVE CONNECTOR M12 FROM THE PCB
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
DIVERTER VALVE MICROSWITCH (RESISTANCE)
DISCONNECT PLUG CONN
OBSERVATION DHW MICROSWITCH DISCONNECTED
REMOVE THE MICROSWITCH FROM THE TOP OF THE DIVERTER VALVE AND PLACE IN A SAFE POSITION
GAS VALVE MODULATION RESISTANCE
DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID
SUMMER/WINTER SWITCH RESISTANCE
REMOVE 1 CONNECTOR F
VOLTAGE EXTERNAL PROGRAMMER
REMOVE CONTROL BOX COVER
VOLTAGE ROOM STAT
REMOVE CONTROL BOX COVER
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
GAS INLET PRESSURE
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
GAS VALVE MODULATION RESISTANCE
DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR M4 FROM THE PCB
GAS VALVE MODULATION RESISTANCE
DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID
BURNER CONDITION
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
RESISTANCE GAS VALVE MAIN SOLENOID
REMOVE THE PLUG FROM THE GAS VALVE
INSPECTION DIVERTER MOVEMENT
REMOVE THE MICROSWITCH FROM THE TOP OF THE DIVERTER VALVE AND PLACE IN A SAFE POSITION
GAS VALVE VOLTAGE
REMOVE PLASTIC COVER FROM THE PCB
USE INSULATION MAT AS REQUIRED
GAS VALVE SOLENOID RESISTANCE
REMOVE THE PLUG FROM THE GAS VALVE
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
FUSE F1 RESISTANCE
REMOVE CONTROL BOX COVER
REMOVE FUSE F1 FROM PCB
GAS PRESSURE ON IGNITION (BURNER)
ON/OFF SWITCH IN ON
GAS INLET PRESSURE
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
FLAME SENSE ELECTRODE AND LEAD
DISCONNECT FLAME SENSOR LEAD FROM ELECTRODE AND PCB.
GAS VALVE MODULATION RESISTANCE
DISCONNECT VIOLET LEADS FROM THE MODULATING SOLENOID
GAS PRESSURE ON IGNITION (BURNER)
ON/OFF SWITCH IN ON
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
DIFFERENTIAL TEMPERATURE (HEATING)
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES
HEAT EXCHANGER INSPECTION
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
GAS PRESSURE - CH
ATTACH U-GAUGE TO GAS VALVE OUTLET PRESSURE TEST POINT
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
DIFFERENTIAL TEMPERATURE (HEATING)
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
BURNER INJECTOR CONDITION
REMOVE GAS RAIL FROM BOILER FOR INSPECTION
BURNER CONDITION
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
HEAT EXCHANGER INSPECTION
REMOVE THE BURNER ASSEMBLY FROM THE BOILER
LOW WATER PRESSURE SWITCH MADE
LOCATE AND REMOVE CONNECTOR M12 FROM THE PCB
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
DIVERTER VALVE MICROSWITCH (RESISTANCE)
DISCONNECT PLUG CONN
OBSERVATION DHW MICROSWITCH DISCONNECTED
REMOVE THE MICROSWITCH FROM THE TOP OF THE DIVERTER VALVE AND PLACE IN A SAFE POSITION
FLOW BLOCKAGE OR DAMAGE
BOILERS DHW CIRCUIT FULLY DRAINED AND DISCHARGED
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
RESISTANCE DHW SENSOR
DISCONNECT PLUG FROM DHW SENSOR (PURPLE AND GREY LEADS)
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
PRESSURE APS SWITCHING AT PCB
REMOVE PLASTIC COVER FROM THE PCB
REMOVE AIR PRESSURE SWITCH CONNECTOR FROM M3 ON THE PCB
OBSERVATION SPARKING APS PROVED
CONNECT THE AIR PRESSURE SWITCH CHARGE KIT TO +VE CONNECTION ON THE AIR PRESSURE SWITCH
VOLTAGE EXTERNAL PROGRAMMER
REMOVE CONTROL BOX COVER
VOLTAGE ROOM STAT
REMOVE CONTROL BOX COVER
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
CH POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
RESISTANCE HARNESS AND FLOW SENSOR
DISCONNECT SENSOR PLUG FROM THE PCB
RESISTANCE HARNESS AND DHW SENSOR
DISCONNECT M12 PLUG FROM THE PCB
DHW POTENTIOMETER RESISTANCE
REMOVE CONTROL BOX COVER
DISCONNECT PLUG MARKED M11
DHW PUMP RUNS
REMOVE THE VENT PLUG FROM THE PUMP
PRESSURE BURNER MAX AND MIN
LOOSEN THE OUTLET TEST POINT SCREW (P2) AND ATTACH U-GAUGE TO THE TEST POINT
DIFFERENTIAL TEMPERATURE (HEATING)
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES
GAS INLET PRESSURE
ATTACH U-GAUGE TO GAS VALVE INLET PRESSURE TEST POINT
OBSERVATION RUN BOILER UP TO TEMPERATURE
ATTACH A TEMPERATURE CLAMP/PROBE TO THE FLOW PIPE (JUST ABOVE THE OVERHEAT STAT)
RESISTANCE FLOW SENSOR
DISCONNECT PLUG FROM CH SENSOR (YELLOW LEADS)
FUSE F1 RESISTANCE
REMOVE CONTROL BOX COVER
REMOVE FUSE F1 FROM PCB