XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

MAIN COMBI 25 AND 30 ECO ELITE ERP

GLOBALLY REPLACED

Next: &1, *

CASE OFF

Next: &1045, !f2

DHW FLOW RATE

Next: &2543, f96

DOES FAN RUN ON DHW DEMAND

Next: &334, f2555

BURNER IGNITES AND ESTABLISHES

{SELHWCHON}

Next: &248, ?186, ?190, ?192

OPERATION DHW

APPLIANCE DHW THERMO

Next: &2911, ?249, ?251, ?253, ?257

DOES PUMP RUN

Next: &185, f2867

OPERATION CH

{SELHWCHON}
CH THERMOSTAT SET TO MAX

Next: &nff, ?360, ?362, ?368

OVERHEAT INVESTIGATION

OUT OF MODEL

Next: &nff, f438

E20 FAULT CODE

OUT OF MODEL

Next: &nff, f585

E50 FAULT CODE

OUT OF MODEL

Next: &nff, f591

E119 FAULT CODE

OUT OF MODEL

Next: &nff, f598

E125 FAULT CODE

OUT OF MODEL

Next: &nff, f628

E160 FAULT CODE

OUT OF MODEL

Next: &nff, f721

FUSE FURTHER INVESTIGATION

OUT OF MODEL

Next: &nff, f806

E168 FAULT CODE

E168 FAULT CODE
T

Next: &nff, f1615

E156 FAULT CODE

Next: &nff, !f1022

POWER UP

{SELHWCHON}
ENSURE THERE ARE NO DEMANDS

Next: &1093, ?1465, ?1467

BOILER ENTERS STANDBY MODE

{SELHWCHON}
ENSUR

Next: &3, ?1094, ?1368, ?2771

E164 FAULT CODE

OUT OF MODEL

Next: &nff, f1176

INFORMATION INTELLIGENT PREHEAT

THE BOILER INCORPORA

Next: &nff, !f2173

OBSERVATION DHW DEMAND RECOGNISED

SELECTOR SWITCH ON HOT WATER
RUN DHW TAP AT 3 LITRES PER MINUTE

Next: &105, f2545

OBSERVATION CH DEMAND RECOGNISED

SELECTOR SWITCH ON DHW AND CH
APPLIANCE DHW THERMOSTAT TO MIN

Next: &357, f2594

OBSERVATION DOES DHW DEMAND END

APPLIANCE DHW THERMOSTAT TO MIN

Next: &2593, f2912

SF OR P CALIBRATION FUNCTION

INTENTIONALLY BLANK - HEADER FOR FAULT CODE

Next: &nff, f2916

LITE DIAGNOSTIC

DIAGNOSIS RELIES ON

Next: &nff, !f2920

QUICK ACCESS DATA AND INFORMATION

THE TABLE BELOW SHOW

Next: &nff, !f2922

HEADER FOR QADAI FLOW THERMISTOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2924

HEADER FOR QADAI GAS VALVE RESISTANCE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2928

HEADER FOR QADAI GAS VALVE VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2932

HEADER FOR QADAI SPARK GENERATOR RESISTANCE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2936

HEADER FOR QADAI PUMP RESISTANCE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2940

HEADER FOR QADAI FAN AC VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2944

HEADER FOR QADAI FAN AC RESISTANCE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2948

HEADER FOR QADAI PUMP VOLTAGE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2952

HEADER FOR QADAI DIVERTER VALVE RESISTANCE

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2956

HEADER FOR QADAI DHW SENSOR

INTENTIONALLY BLANK - HEADER FOR QADAI

Next: &nff, f2960

TEMP LOW

SENSOR - BOILER - SPARE

Next: End

LOW CAUSING E164

SYSTEM PRESSURE

Next: End

BLOCKED/FAULTY CAUSING E164

SWITCH - PRESSURE - HEATING (WATER PRESSURE)

Next: End

E164

PUMP

Next: End

POOR FLOW RATE

FLOW REGULATOR

Next: End

FROST PROTECTION

SENSOR - NTC (DHW)

Next: End

LEAK OR OPEN TAP MAKING FLOW SWITCH

HOT WATER TAP OR PIPEWORK

Next: End

STUCK MADE

FLOW REGULATOR

Next: End

FAULTY CASUING DEMAND WHEN NONE PRESENT

SENSOR - HALL EFFECT

Next: End

FROST PROTECTION

SENSOR - BOILER - SPARE

Next: End

BLOWN

FUSE 3AMP

Next: End

BLOWN

FUSE 2 AMP (LIVE)

Next: End

BLOWN

FUSE 2 AMP (NEUTRAL)

Next: End

ERRATIC TEMPERATURE DISPLAY

SENSOR - BOILER - SPARE

Next: End

SOLENOID CAUSING E168

GAS VALVE

Next: End

CAUSING E168

MOTOR - 3 WAY VALVE

Next: End

CAUSING E168

SPARK GENERATOR

Next: End

AC SIDE CAUSING E168

FAN

Next: End

DC SIDE CAUSING E168

FAN

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFANE168

SENSOR - BOILER - SPARE

Next: End

INSUFFICIENT

WATER SUPPLY

Next: End

COOL HW

SENSOR - NTC (DHW)

Next: End

DHW COOL RADS COOL

SENSOR - BOILER - SPARE

Next: End

INSUFFICIENT PREVENTING RECTIFICATION

GAS INLET PRESSURE

Next: End

BLANK FOR CASE REMOVAL

Z DIRECTION CHOICE OR CONTINUE

Next: End

INSUFFICIENT CAUSING BAFFLING

GAS INLET PRESSURE

Next: End

BLOCKED CAUSING BAFFLING

BODY - CONDENSATE TRAP

Next: End

OVERHEAT

TAP - ISOLATION - RETURN (FILTER)

Next: End

OVERHEAT DHW DIFF OK

TAP - ISOLATION - RETURN (FILTER)

Next: End

BLOCKAGE CASUING POOR DHW

3 WAY VALVE ASSEMBLY

Next: End

RESTRICTED LOWERING OUTPUT

BURNER

Next: End

FLUEWAYS RESTRICTED LOWERING OUTPUT

HEAT EXCHANGER ASSEMBLY

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFANOH

THERMOSTAT - LIMIT

Next: End

NO RESET OVERHEAT

SWITCH - SELECTOR - 4 POSITION

Next: End

BLANK FOR INFORMATION INTELLIGENT PREHEAT

Z DIRECTION CHOICE OR CONTINUE

Next: End

RESTRITED BLOCKED OR SPLIT PREVENTING IGNITON

PIPE - PRESSURE SWITCH

Next: End

SPARK GENERATOR HARNESS SECTION FAULTY PREVENTING SPARKING

HARNESS - WIRING - HIGH VOLTAGE

Next: End

RESTRICTED/BLOCKED OR SPLIT CAUSING BAFFLING

PIPE - PRESSURE SWITCH

Next: End

RESTRICTED REDUCING OUTPUT

INJECTOR

Next: End

EXTERNAL MIXING LOWERING DHW TEMPERATURE

EXTERNAL MIXING

Next: End

GAS VALVE DAMAGED PCB

PCB AND GAS VALVE

Next: End

BLOCKED PREVENTING BURNER ESTABLISHING

BODY - CONDENSATE TRAP

Next: End

NO RECTIFICATION VOLTAGE

PCB

Next: End

E125 FAULT CODE

TAP - ISOLATION - RETURN (FILTER)

Next: End

RESTRICTED/BLOCKED CAUSING E125

HEAT EXCHANGER - DHW

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFANE168

THERMOSTAT - LIMIT

Next: End

NO FANNO SUPPLY VOLTAGEFANE168

SENSOR - NTC (DHW)

Next: End

LOW CAUSING E168

SYSTEM PRESSURE

Next: End

BLOCKED/FAULTY CAUSING E168

SWITCH - PRESSURE - HEATING (WATER PRESSURE)

Next: End

SPARK ELECTRODES CAUSING E168

UNIT - IGNITION AND IONISATION - SPARE

Next: End

NO MOVEMENT

FLOW REGULATOR

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFAN

SENSOR - BOILER - SPARE

Next: End

NO FANNO SUPPLY VOLTAGEFAN

SENSOR - NTC (DHW)

Next: End

LOW PREVENTING FAN RUNNING

SYSTEM PRESSURE

Next: End

BLOCKED/FAULTY PREVENTING DEMAND

SWITCH - PRESSURE - HEATING (WATER PRESSURE)

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFAN

THERMOSTAT - LIMIT

Next: End

FAN AC SECTION FAULTY PREVENTING FAN RUNNING

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DHW HOT THEN COLD

PUMP

Next: End

BLOCKAGE CAUSING DHW TO RUN HOT THEN COLD

3 WAY VALVE ASSEMBLY

Next: End

OPERATION DHW DHW RUNS HOT THEN COLD

SENSOR - NTC (DHW)

Next: End

MISSING OR OPEN CIRCUIT

CABLE - INTEGRAL TIMER

Next: End

OPERATION DHW DHW RUNS HOT THEN COLD

SENSOR - BOILER - SPARE

Next: End

RESTRICTED CAUSING WRONG MIX/BAFFLING

PLATE - ORIFICE

Next: End

RESTRICTED CAUSING NO DROP

PLATE - ORIFICE

Next: End

RESTRICTED CAUSING WRONG MIX/NO IGNITION

PLATE - ORIFICE

Next: End

RESTRICTED CASUING LOW OUTPUT

PLATE - ORIFICE

Next: End

AIR IN BOILER OR SYSTEM CAUSING POOR CH OPERATION

SYSTEM PRESSURE / AIR

Next: End

BLOCKED PREVENTING IGNITION

BODY - CONDENSATE TRAP

Next: End

DHW ONE FAULTY PREHEAT ON

SPINDLE / KNOB ALIGNMENT

Next: End

DHW ONE FAULTY DHW TOO HOT

SPINDLE / KNOB ALIGNMENT

Next: End

CH ONE FAULTY LOW CH TEMPERATURE

SPINDLE / KNOB ALIGNMENT

Next: End

DHW ONE FAULTY DHW TOO COOL

SPINDLE / KNOB ALIGNMENT

Next: End

SHORTED CAUSING BLANK DISPLAY

SENSOR - HALL EFFECT

Next: End

SHORTED CASUING BLANK DISPLAY

HARNESS - WIRING

Next: End

SHORTED BLOWING FUSE

SPARK GENERATOR

Next: End

NO CH SWITCH

SWITCH - SELECTOR - 4 POSITION

Next: End

SECTION FROM TERMINAL STRIP TO SELECTOR SWITCH

HARNESS - WIRING - 5 + 1 TERMINAL

Next: End

OBSERVATION PUMP RUNS

PCB

Next: End

SPINDLE SEIZED

3 WAY VALVE ASSEMBLY

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP PCB

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS

RELAY - PCB

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP PCB OVERHEAT

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP OVERHEAT

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS OVERHEAT

RELAY - PCB

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP PCB E125

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP E125

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS E125

RELAY - PCB

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP PCB E164

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS - OPEN TO PUMP E164

HARNESS - WIRING - HIGH VOLTAGE

Next: End

OBSERVATION PUMP RUNS E164

RELAY - PCB

Next: End

PUMP SECTION FAULTY BLOWING FUSE

HARNESS - WIRING - HIGH VOLTAGE

Next: End

PUMP SECTION FAULTY CAUSING E168

HARNESS - WIRING - HIGH VOLTAGE

Next: End

STUCK AFTER DEMAND

FLOW REGULATOR

Next: End

BLANK FOR LITE DIAGNOSTIC

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLANK FOR QADAI

Z DIRECTION CHOICE OR CONTINUE

Next: End

QADAI

SENSOR - BOILER - SPARE

Next: End

QADAI

GAS VALVE

Next: End

QADAI

SPARK GENERATOR

Next: End

QADAI

PUMP

Next: End

QADAI NO POWER TO FAN AC

PCB

Next: End

QADAI AC

FAN

Next: End

QADAI NO POWER TO PUMP

RELAY - PCB

Next: End

QADAI

MOTOR - 3 WAY VALVE

Next: End

QADAI

SENSOR - NTC (DHW)

Next: End

FAN RUNSDHW OPERATION DHW TOO HOT

SENSOR - NTC (DHW)

Next: End

FLUEWAYS RESTRICTED CAUSING BAFFLING

HEAT EXCHANGER ASSEMBLY

Next: End

NO OR LOW CHARGE

EXPANSION VESSEL

Next: End

FULLY OR PARTIALLY CLOSED

FLOW AND RETURN VALVES

Next: End

RADS COOL

PUMP

Next: End

BLANK FOR TYPE OF DIAGNOSTIC PROCEDURE

Z DIRECTION CHOICE OR CONTINUE

Next: End

BYPASS PASSING WHEN SHOULDNT

3 WAY VALVE ASSEMBLY

Next: End

BLOCKED

TAP - ISOLATION - RETURN (FILTER)

Next: End

F5 FAULT CODE

PUMP

Next: End

OVERHEAT

SENSOR - NTC (DHW)

Next: End

OVERHEAT

SENSOR - BOILER - SPARE

Next: End

INSUFFICIENT CAUSING LOW OUTPUT

GAS INLET PRESSURE

Next: End

DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO CH

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DIVERTER VALVE SECTION FAULTY PREVENTING MOVING TO DHW

HARNESS - WIRING - HIGH VOLTAGE

Next: End

FAN RUNS DHWNO SUPPLY VOLTAGEFANE20

SENSOR - BOILER - SPARE

Next: End

NO FANNO SUPPLY VOLTAGEFANE50

SENSOR - NTC (DHW)

Next: End

LOW CAUSING E119

SYSTEM PRESSURE

Next: End

BLOCKED/FAULTY CAUSING E119

SWITCH - PRESSURE - HEATING (WATER PRESSURE)

Next: End

E125

PUMP

Next: End

E125

SENSOR - BOILER - SPARE

Next: End

E125

SENSOR - NTC (DHW)

Next: End

NO RESET

SWITCH - SELECTOR - 4 POSITION

Next: End

FAN AC SECTION FAULTY PREVENTING FAN RUNNING CAUSING E160

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DC SECTION TO FAN FAULTY CAUSING E160

HARNESS - WIRING

Next: End

BLANK FOR FAULT CODEES

Z DIRECTION CHOICE OR CONTINUE

Next: End

SOLENOID BLOWING FUSE

GAS VALVE

Next: End

DC SIDE BLOWING FUSE

FAN

Next: End

SHORTED BLOWING FUSE

MOTOR - 3 WAY VALVE

Next: End

AC SIDE BLOWING FUSE

FAN

Next: End

POOR FLOW RATE

TAP - ISOLATION - DHW INLET

Next: End

STUCK IN E164

PCB

Next: End

CORRECTLY ACTIVATED/NORMAL OPERATION

FROST PROTECTION

Next: End

GIVING DEMAND WHEN SHOULD NOT

INTEGRAL TIMER / WIRELESS CONTROLS

Next: End

BLANK FOR FUSE FURTHER INVESTIGATION F1

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLANK FOR FUSE FURTHER INVESTIGATION F2

Z DIRECTION CHOICE OR CONTINUE

Next: End

BLANK FOR FUSE FURTHER INVESTIGATION F3

Z DIRECTION CHOICE OR CONTINUE

Next: End

NOT RUNNING WITH DEMAND

FAN

Next: End

GAS VALVE SECTION FAULTY CAUSING E168

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DIVERTER VALVE SECTION FAULTY CAUSING E168

HARNESS - WIRING - HIGH VOLTAGE

Next: End

SPARK GENERATOR SECTION FAULTY CAUSING E168

HARNESS - WIRING - HIGH VOLTAGE

Next: End

FAN AC SECTION FAULTY CAUSING E168

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DC SECTION TO FAN FAULTY CASUING E168

HARNESS - WIRING

Next: End

PRIMARY SENSOR SECTION FAULTY CAUSING E168

HARNESS - WIRING

Next: End

NOT MOVING TO CH CAUSING OVERHEAT

MOTOR - 3 WAY VALVE

Next: End

RESTRICTED/BLOCKED CAUSING OVERHEAT

HEAT EXCHANGER - DHW

Next: End

NOT MOVING TO CH CAUSING OVERHEAT 2

MOTOR - 3 WAY VALVE

Next: End

RESTRICTED/BLOCKED CAUSING LOW DHW TEMPERATURE

HEAT EXCHANGER - DHW

Next: End

WATERWAYS RESTRICTED CAUSING POOR DHW

HEAT EXCHANGER ASSEMBLY

Next: End

OPEN CIRCUIT OR POOR CONDITION PREVENTING SPARKING

SPARK PLUG AND HT LEAD

Next: End

OPEN CIRCUIT OR POOR CONDITION PREVENTING IGNITON

SPARK PLUG AND HT LEAD

Next: End

FLUEWAYS RESTRICTED PREVENTING IGNITON

HEAT EXCHANGER ASSEMBLY

Next: End

INSUFFICIENT PREVENTING IGNITON

GAS INLET PRESSURE

Next: End

NO VOLTAGE TO GAS VALVE

PCB

Next: End

GAS VALVE HARNESS DAMAGED PCB

PCB AND GAS VALVE HARNESS

Next: End

GAS VALVE SECTION FAULTY PREVENTING INLET DROP

HARNESS - WIRING - HIGH VOLTAGE

Next: End

FLUEWAYS RESTRICTED PREVETING INLET PRESSURE DROP

HEAT EXCHANGER ASSEMBLY

Next: End

RESTRICTED OR BLOCKED NO IGNITION

PLENUM - AIR INTAKE

Next: End

RESTRICTED OR BLOCKED CAUSING NO INLET DROP

PIPE - INDUCTION RESONANCE

Next: End

RESTRICTED OR BLOCKED NO IGNITION 2

PLENUM - AIR INTAKE

Next: End

RESTRICTED OR BLOCKED CAUSING BAFFLING

PLENUM - AIR INTAKE

Next: End

RESTRICTED OR BLOCKED CAUSING BAFFLING

PIPE - INDUCTION RESONANCE

Next: End

RESTRICTED LOWERING OUTPUT

PIPE - INDUCTION RESONANCE

Next: End

RESTRICTED LOWERING OUTPUT

PLENUM - AIR INTAKE

Next: End

DETECTION ELECTRODE PREVENTING RECTIFICATION

UNIT - IGNITION AND IONISATION - SPARE

Next: End

WATERWAYS RESTRICTED CAUSING E125

HEAT EXCHANGER ASSEMBLY

Next: End

ALL OKAY

BOILER LOCKOUT

Next: End

OVERHEAT STAT SECTION FAULTY CAUSING E168

HARNESS - WIRING

Next: End

DHW SENSOR SECTION FAULTY CASUING E168

HARNESS - WIRING

Next: End

NOT SENSING MAGNET FROM FLOW SWITCH ASSEMBLY

SENSOR - HALL EFFECT

Next: End

DHW SENSOR SECTION FAULTY PREVENTING DEMAND

HARNESS - WIRING

Next: End

WATERWAYS RESTRICTED CAUSING DHW TO RUN HOT AND COLD

HEAT EXCHANGER ASSEMBLY

Next: End

NOT GIVING DEMAND WHEN SHOULD

INTEGRAL TIMER / WIRELESS CONTROLS

Next: End

WRONG MIX CASUING BAFFLING

GAS VALVE

Next: End

SOLENOID OK BUT NOT OPENING

GAS VALVE

Next: End

SPARK GAP INCORRECT PREVENTING IGNITION

UNIT - IGNITION AND IONISATION - SPARE

Next: End

SPARK GAP FROM BURNER INCORRECT PREVENTING IGNITION

UNIT - IGNITION AND IONISATION - SPARE

Next: End

SPARK GAP INCORRECT OR OPEN CIRCUIT PREVENTING SPARKING

UNIT - IGNITION AND IONISATION - SPARE

Next: End

CAUSING E168

PCB

Next: End

NOT MAKING SPARKS

SPARK GENERATOR

Next: End

NO FANB4 OP SEQ

SWITCH - SELECTOR - 4 POSITION

Next: End

NO DISPLAY

PCB

Next: End

PCB FUSE BLOWING

FUSE GONE PCB

Next: End

SPARK GENERATOR SECTION SHORTED

HARNESS - WIRING - HIGH VOLTAGE

Next: End

SELECTOR SWITCH TO PCB SECTION FAULTY

HARNESS - WIRING - 5 + 1 TERMINAL

Next: End

OBSERVATION PUMP RUNS

PUMP

Next: End

PASSING TO RADIATORS

3 WAY VALVE ASSEMBLY

Next: End

E168

PUMP

Next: End

STUCK AFTER DEMAND

SENSOR - HALL EFFECT

Next: End

NORMAL OPERATION

CALIBRATION FUNCTION

Next: End

SENSOR TEMP FLOW

RESULT AS EXPECTED

Next: End

GAS VALVE

RESULT AS EXPECTED

Next: End

PCB POWER TO GAS VALVE

RESULT AS EXPECTED

Next: End

SPARK GENERATOR

RESULT AS EXPECTED

Next: End

PUMP

RESULT AS EXPECTED

Next: End

PCB POWER TO FAN AC

RESULT AS EXPECTED

Next: End

FAN AC

RESULT AS EXPECTED

Next: End

PCB POWER TO PUMP

RESULT AS EXPECTED

Next: End

DIVERTER VALVE HEAD

RESULT AS EXPECTED

Next: End

DHW SENSOR

RESULT AS EXPECTED

Next: End

EXPANSION VESSEL CONNECTION

PIPE ASSEMBLY - RETURN/PUMP (EXPANSION VESSEL PIPE)

Next: End

OVERHEAT

TEMPERATURE OVERHEAT

Next: End

CUTTING OFF

THERMOSTAT - LIMIT

Next: End

NOT MOVING TO CH

MOTOR - 3 WAY VALVE

Next: End

NOT MOVING TO DHW POSITION

MOTOR - 3 WAY VALVE

Next: End

PRIMARY SENSOR SECTION FAULTY CAUSING E20

HARNESS - WIRING

Next: End

STUCK IN E20

PCB

Next: End

STUCK IN E50

PCB

Next: End

STUCK IN E119

PCB

Next: End

STUCK IN E125

PCB

Next: End

DIVERTER VALVE SECTION FAULTY BLOWING FUSE

HARNESS - WIRING - HIGH VOLTAGE

Next: End

DC SECTION TO FAN CAUSING FUSE TO BLOW

HARNESS - WIRING

Next: End

GAS VALVE SECTION FAULTY BLOWING FUSE

HARNESS - WIRING - HIGH VOLTAGE

Next: End

FAN AC SECTION FAULTY BLOWING FUSE

HARNESS - WIRING - HIGH VOLTAGE

Next: End

FAN RUNS CONTINUALLY

CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE

Next: p1095

DHW OR CH DEMAND LED ILLUMINATED

CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE

Next: p1430

DISPLAY DOES NOT ILLUMINATE

CHARACTERISTIC TEST FROM POWER UP

Next: p1469

DISPLAY ILLUMINATES BUT TEMPERATURE DISPLAYED ERRATIC

CHARACTERISTIC TEST FROM POWER UP

Next: p1516

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES

Next: p2174

BURNER IGNITES BUT BAFFLES OUT OR IS NOISY

CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES

Next: p191

BURNER IGNITES BUT DOES NOT ESTABLISH

CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES

Next: p193

ELECTRODE UNSATISFACTORY

CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS

Next: !p2770

IGNITION LEAD UNSATISFACTORY

CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER

Next: !p2183

ELECTRODE UNSATISFACTORY

CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS

Next: !p2768

IGNITION LEADS UNSATISFACTORY

CHARACTERISTIC TEST FROM INSPECTION IGNITION ELECTRODES & LEADS

Next: !p2395

HEAT EXCHANGER FLUEWAYS RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

Next: !p2401

IGNITION ELECTRODES UNSATISFACTORY

CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

Next: !p2769

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

Next: !p2405

GAS INLET PRESSURE UNSATISFACTORY

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: !p2407

GAS INLET PRESSURE OK BUT NO DROP SEEN

CHARACTERISTIC TEST FROM PRESSURE GAS INLET AND DROP

Next: p2410

HEAT EXCHANGER FLUEWAYS RESTRICTED

CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

Next: !p2432

BURNER RESTRICTED AND/OR DAMAGED

CHARACTERISTIC TEST FROM INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

Next: !p2434

AIR INTAKE PIPE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2437

FAN AIR INTAKE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2439

AIR INTAKE PIPE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2442

FAN AIR INTAKE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2444

AIR INTAKE PIPE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2462

FAN AIR INTAKE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2461

AIR INTAKE PIPE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2465

FAN AIR INTAKE RESTRICTED OR BLOCKED

CHARACTERISTIC TEST FROM INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

Next: !p2467

DHW TOO HOT

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p2775

DHW TOO COOL AND RADIATORS REMAIN COOL WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p2779

DHW TOO COOL AND RADIATORS BEGIN TO HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p254

NO VOLTAGE PRESENT ON TEST 1

CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION

Next: !p2548

VOLTAGE DOES NOT DROP TO 0 (ZERO) ON TEST 2

CHARACTERISTIC TEST FROM DHW FLOW SWITCH OPERATION

Next: p2550

DHW RUNS HOT AND COLD

CHARACTERISTIC TEST FROM OPERATION DHW

Next: p2656

VOLTAGE MISSING

CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER

Next: p2602

NO INTEGRAL TIMER FITTED

CHARACTERISTIC TEST FROM VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER

Next: p2604

DHW LED FLASHES

CHARACTERISTIC TEST FROM BOILER ENTERS STANDBY MODE

Next: p2772

BOILER REACHES TEMPERATURE BUT RADIATORS REMAIN COLD

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2671

BOILER AND SYSTEM TEMPERATURE LOW

CHARACTERISTIC TEST FROM OPERATION CH

Next: p2817

EXCESSIVE SYSTEM PRESSURE RISE

CHARACTERISTIC TEST FROM OPERATION CH

Next: p369

BOILER TEMP GOES ABOVE 90 DEGREES AND DOESNT CUT OFF

CHARACTERISTIC TEST FROM CH TEST OVERHEAT

Next: !p512

BOILER LOCKS OUT ON OVERHEAT BEFORE REACHING 85 DEGREES

CHARACTERISTIC TEST FROM CH TEST OVERHEAT

Next: !p516

SYSTEM PRESSURE CHECK

Next: p1183, !f1178

RESISTANCE WATER PRESSURE SWITCH

REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH

Next: !p1181, !f1182

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: p1433, !f1434

VOLTAGE FROM SWITCH LIVE

{SELHWCHON}
NO DEMANDS FOR CH
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p1460, !f1461

RESISTANCE FUSE F1 (FUSED SPUR)

Next: !p1472, f1473

FUSE FURTHER INVESTIGATION F1

Next: !p1474, !f1475

RESISTANCE FUSE F2 ( APPLIANCE)

REMOVE CONTROL BOX COVER
REMOVE THE FUSE AND HOLDER FROM THE LIVE (BROWN)

Next: p1478, f1479

FUSE FURTHER INVESTIGATION F2

Next: !p1480, !f1481

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p1519, !f1520

RESISTANCE PUMP AND HARNESS

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p1616, f1617

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: !p2910, !f2909

RESISTANCE GAS VALVE

DISCONNECT THE LEAD FROM THE GAS VALVE

Next: !p1622, !f1623

RESISTANCE DIVERTER VALVE HEAD

REMOVE DIVERTER VALVE HEAD FROM BODY

Next: !p1626, !f1627

RESISTANCE IGNITER

REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR

Next: !p1630, !f1631

RESISTANCE AC FAN

REMOVE THE 3 WIRE CONNECTOR FROM THE FAN

Next: !p1634, !f1635

RESISTANCE FAN DC

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN

Next: !p1637, !f1638

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p1642, !f1643

INSPECTION DIVERTER VALVE POSITION CH

{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR

Next: p2045, f2046

VOLTAGE DIVERTER VALVE PCB CH

FUNCTION SELECTOR IN

Next: p2047, !f2048

INSPECTION DIVERTER VALVE POSITION CH

{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR

Next: p2056, f2057

VOLTAGE DIVERTER VALVE PCB CH

FUNCTION SELECTOR IN

Next: p2058, !f2059

TEMPERATURE DIFFERENTIAL CH

{SELHWCHON}
APPLI

Next: !p2067, f2068

DIVERTER VALVE BLOCKAGE

ISOLATE AND DRAIN DO

Next: !p2069, !f2070

RESISTANCE SENSOR OVERHEAT STAT

REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT

Next: !p2130, !f2131

RESISTANCE SELECTOR SWITCH (RESET)

{SELHWCHON}
REMOV

Next: !p2133, !f2134

INSPECTION IGNITION ELECTRODES & LEADS

REMOVED ELECTRODE ASSEMBLY
DISCONNECT IGNITION LEADS FROM SPARK GENERATOR, NOTE CONNECTIONS

Next: p2179, ?2180, ?2182

RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS

DISCONNECT CONNECTOR MARKED X3 FROM PCB

Next: !p2413, f2414

RESISTANCE GAS VALVE

DISCONNECT THE LEAD FROM THE GAS VALVE

Next: !p2415, !f2416

RESISTANCE GAS VALVE

DISCONNECT THE LEAD FROM THE GAS VALVE

Next: !p2419, !f2420

RESISTANCE DETECTION LEAD

DISCONNECT INLINE CO

Next: !p2475, !f2476

INSPECTION RETURN FILTER

DRAIN BOILER HEATING CIRCUIT

Next: !p2481, !f2482

RESISTANCE SENSOR OVERHEAT STAT

REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT

Next: !p2492, !f2493

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: !p2497, !f2498

SYSTEM PRESSURE CHECK

Next: p2501, !f2502

DHW FLOW SWITCH OPERATION

SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p2546, ?2547, ?2549

RESISTANCE SENSOR TEMP PRIMARY AND HARNESS

REMOVE THE PLUG X401 FROM THE PCB

Next: p2556, f2557

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p2558, !f2559

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: !p2562, !f2563

SYSTEM PRESSURE CHECK

Next: p2566, !f2567

RESISTANCE SENSOR OVERHEAT STAT

REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT

Next: !p2572, !f2573

TEMPERATURE DIFFERENTIAL CH

{SELHWCHON}
APPLI

Next: !p2589, f2590

DIVERTER VALVE BLOCKAGE

ISOLATE AND DRAIN DO

Next: !p2591, !f2592

VOLTAGE FROM SELECTOR SWITCH

{SELHWCHON}
CH THERMOSTAT TO MAX
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2595, f2847

VOLTAGE DIVERTER VALVE PCB

SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p563, !f566

VOLTAGE SELECTOR SWITCH

SELECTOR SWITCH IN HOT WATER

Next: !p2852, f2833

VOLTAGE SELECTOR SWITCH INPUT

SELECTOR SWITCH IN HOT WATER

Next: !p2834, !f2866

RESISTANCE SPARK GENERATOR

REMOVE THE CONNECTOR FROM THE SPARK GENERATOR

Next: !p2845, !f2846

VOLTAGE CONTROL PCB TO PUMP PCB

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2868, !f2869

VOLTAGE CONTROL PCB TO PUMP PCB

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2877, !f2878

VOLTAGE CONTROL PCB TO PUMP PCB

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2886, !f2887

VOLTAGE CONTROL PCB TO PUMP PCB

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2899, !f2900

INSPECTION FLOW SWITCH ASSEMBLY

ISOLATE MAINS WATER

Next: !p2913, !f2914

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p2925, !f2926

RESISTANCE GAS VALVE

DISCONNECT THE LEAD FROM THE GAS VALVE

Next: !p2929, !f2930

GAS VALVE VOLTAGE (PCB)

SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p2933, !f2934

RESISTANCE IGNITER

REMOVE THE FLAME IGNITION HARNESS FROM THE SPARK GENERATOR

Next: !p2937, !f2938

RESISTANCE PUMP AND HARNESS

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: !p2941, !f2942

VOLTAGE AC TO FAN

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: !p2945, !f2946

RESISTANCE AC FAN

REMOVE THE 3 WIRE CONNECTOR FROM THE FAN

Next: !p2949, !f2950

VOLTAGE AC PUMP AT RELAY PCB

UNSCREW THE PUMP REL

Next: !p2953, !f2954

RESISTANCE DIVERTER VALVE HEAD

REMOVE DIVERTER VALVE HEAD FROM BODY

Next: !p2957, !f2958

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: !p2961, !f2962

RESISTANCE OVERHEAT STAT AND HARNESS

UNPLUG CONNECTOR X401 FROM THE PCB

Next: p2087, f2129

TEMPERATURE DIFFERENTIAL CH

{SELHWCHON}
APPLI

Next: !p2053, f2044

VOLTAGE DIVERTER VALVE PCB CH

FUNCTION SELECTOR IN

Next: p556, !f557

RESISTANCE SENSOR TEMP PRIMARY AND HARNESS

REMOVE THE PLUG X401 FROM THE PCB

Next: !p589, f586

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p587, !f588

RESISTANCE SENSOR TEMP DHW AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: !p595, f592

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: !p593, !f594

SYSTEM PRESSURE CHECK

Next: p606, !f600

RESISTANCE WATER PRESSURE SWITCH

REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH

Next: !p1001, !f614

BOILER RESET

Next: p642, f655

RESISTANCE SELECTOR SWITCH (RESET)

{SELHWCHON}
REMOV

Next: !p656, !f657

IS FAN RUNNING

{SELHWCHON}

Next: p722, f723

RESISTANCE FAN HARNESS AC

REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB

Next: p791, !f792

RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS

DISCONNECT CONNECTOR MARKED X3 FROM PCB

Next: p807, f808

RESISTANCE GAS VALVE

DISCONNECT THE LEAD FROM THE GAS VALVE

Next: !p831, !f810

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: !p2908, !f2907

RESISTANCE FAN DC

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN

Next: !p830, !f818

RESISTANCE AC FAN

REMOVE THE 3 WIRE CONNECTOR FROM THE FAN

Next: !p896, !f897

RESISTANCE DIVERTER VALVE HEAD

REMOVE DIVERTER VALVE HEAD FROM BODY

Next: !p828, !f826

DHW ISOLATING VALVE

Next: p1692, !f98

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: !p1020, !f1016

RESISTANCE FAN HARNESS

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB

Next: p1114, !f1115

VOLTAGE FAN SUPPLY

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p1116, !f1117

VOLTAGE DC FAN SPEED ON START UP

Next: !p1306, !f1307

RESISTANCE WATER PRESSURE SWITCH AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: !p1179, f1180

DOES PUMP RUN

Next: p1189, f2898

PUMP LIMPET TEST

Next: p1177, !f1201

IS BOILER TEMP LOW

Next: !p1431, f1443

OBSERVATION ISOLATE DHW DOES DHW DEMAND STOP

ISOLATE THE COLD WATER SUPPLY TO THE APPLIANCE

Next: p1435, !f1436

OBSERVATION REMOVE HALL SENSOR DOES DHW DEMAND STOP

REMOVE DHW HALL SENSOR FROM FLOW VALVE

Next: p1437, !f1438

OBSERVATION DISCONNECT HALL SENSOR DOES DHW DEMAND STOP

REMOVE DHW HALL SENSOR FROM FLOW VALVE
REMOVE CONNECTOR FROM THE HALL SENSOR AND MAKE SAFE

Next: p1439, !f1440

RESISTANCE DHW FLOW SWITCH HARNESS

REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH

Next: !p1441, !f1442

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: p1456, !f1457

VOLTAGE AC FROM INTEGRAL TIMER / WIRELESS RECEIVER

{SELHWCHON}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
ENSURE NO CH DEMAND

Next: !p1462, !f1463

VOLTAGE MAINS POWER INPUT TO APPLIANCE

REMOVE CONTROL BOX COVER

Next: p1470, f1471

VOLTAGE AT PCB MAINS

REMOVE CONTROL BOX COVER

Next: p2829, f1477

FUSE FURTHER INVESTIGATION F3

Next: !p1482, !f1483

RESISTANCE SENSOR TEMP PRIMARY AND HARNESS

REMOVE THE PLUG X401 FROM THE PCB

Next: !p1517, f1518

VOLTAGE DC PCB SPEED REQUEST

Next: !p1525, !f1526

RESISTANCE FAN HARNESS

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB

Next: p1552, !f1553

VOLTAGE FAN SUPPLY

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p1554, !f1555

VOLTAGE DC PCB SPEED REQUEST

Next: !p1556, !f1557

RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS

DISCONNECT CONNECTOR MARKED X3 FROM PCB

Next: p1620, f1621

RESISTANCE DIVERTER VALVE AND HARNESS

REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY

Next: p1624, f1625

RESISTANCE IGNITER AND HARNESS

REMOVE CONNECTOR X2 FROM THE PCB

Next: p1628, f1629

RESISTANCE FAN AND HARNESS AC

REMOVE CONNECTOR X2 FROM THE PCB

Next: p1632, f1633

RESISTANCE FAN AND HARNESS DC

DISCONNECT CONNECTOR X401 FROM THE PCB

Next: p1639, f1636

RESISTANCE SENSOR TEMP PRIMARY AND HARNESS

REMOVE THE PLUG X401 FROM THE PCB

Next: p2490, f1641

WATER SUPPLY TO PREMISES

TURN ON A COLD WATER TAP

Next: p97, !f1696

PUMP LIMPET TEST

Next: p1752, !f1753

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: p1754, !f1755

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: p2064, !f1757

GAS INLET PRESSURE

{SELHWCHON}
SET D

Next: p2246, !f203

GAS INLET PRESSURE

{SELHWCHON}
SET D

Next: p2468, !f195

INSPECTION CONDENSATE PIPE

Next: p2267, !f205

TEMPERATURE DIFFERENTIAL CH

{SELHWCHON}
APPLI

Next: p453, f2055

INSPECTION BURNER

REMOVE THE FRONT OF THE COMBUSTION CHAMBER

Next: p206, !f207

INSPECTION RETURN FILTER

DRAIN BOILER HEATING CIRCUIT

Next: !p2051, !f2052

RESISTANCE DIVERTER HARNESS

REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR

Next: !p2049, !f2050

INSPECTION RETURN FILTER

DRAIN BOILER HEATING CIRCUIT

Next: !p2062, !f2063

RESISTANCE DIVERTER HARNESS

REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR

Next: !p2060, !f2061

INSPECTION HEAT EXCHANGER

Next: p2609, !f305

TEMPERATURE DIFFERENTIAL DHW

ATTACH TEMPERATURE C

Next: p2369, f2066

INSPECTION BURNER

REMOVE THE FRONT OF THE COMBUSTION CHAMBER

Next: p2071, !f2072

INSPECTION HEAT EXCHANGER

Next: p2618, !f2074

BOILER RESET

Next: p439, f2132

INSPECTION COMPENSATION TUBE

Next: p2688, !f2176

OBSERVATION SPARKING OCCURS

REMOVE THE REARMOST

Next: p2382, f2178

RESISTANCE SPARK GENERATOR HARNESS

REMOVE CONNECTOR FROM SPARK GENERATOR
REMOVE CONNECTOR X2 FROM THE PCB

Next: p2825, !f2185

INSPECTION COMPENSATION TUBE

Next: p202, !f2256

INSPECTION INJECTOR

REMOVE THE INJECTOR

Next: p204, !f2265

INSPECTION FLUE

Next: p2450, !f2277

INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

REMOVE THE AIR INTAKE PIPE

Next: p2347, ?2464, ?2466

INSPECTION INJECTOR

REMOVE THE INJECTOR

Next: p2355, !f2365

INSPECTION FLUE

Next: p2065, !f2366

PRESSURE GAS INLET AND DROP

{SELHWCHON}
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT

Next: p2383, ?2406, ?2408

INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

REMOVE THE AIR INTAKE PIPE

Next: p2384, ?2436, ?2438

INSPECTION FLUE

Next: p2386, !f2387

INSPECTION INJECTOR

REMOVE THE INJECTOR

Next: p2388, !f2389

INSPECTION IGNITION ELECTRODES & LEADS

REMOVED ELECTRODE ASSEMBLY
DISCONNECT IGNITION LEADS FROM SPARK GENERATOR, NOTE CONNECTIONS

Next: p2390, ?2392, ?2394

INSPECTION PRESSURE SENSING VENTURI

REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY

Next: p2396, !f2397

INSPECTION BURNER/ ELECTRODE POSITION/ HEAT EXCHANGER FLUEWAYS

REMOVE BURNER DOOR ASSEMBLY

Next: p2615, ?2400, ?2402, ?2404

GAS VALVE VOLTAGE (PCB)

SELECTOR SWITCH TO HOT WATER
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2411, f2412

RESISTANCE GAS VALVE AND SOLENOID MAIN AND HARNESS

DISCONNECT CONNECTOR MARKED X3 FROM PCB

Next: p2417, f2418

INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

REMOVE THE AIR INTAKE PIPE

Next: p2421, ?2441, ?2443

INSPECTION FLUE

Next: p2423, !f2424

INSPECTION INJECTOR

REMOVE THE INJECTOR

Next: p2425, !f2426

INSPECTION PRESSURE SENSING VENTURI

REMOVE THE COMPENSATION TUBE FROM THE FAN ASSEMBLY

Next: p2427, !f2428

INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS

REMOVE BURNER ASSEMBLY FROM BOILER

Next: p2612, ?2431, ?2433

INSPECTION AIR INTAKE PIPE AND FAN AIR INTAKE

REMOVE THE AIR INTAKE PIPE

Next: p2257, ?2458, ?2460

INSPECTION CONDENSATE PIPE

Next: p2469, !f2470

VOLTAGE RECTIFICATION ON PCB

{SELHWCHON}
REMOVE THE FLAME SENSE LEAD FROM TERMINAL X501

Next: p2471, !f2472

FLAME SENSE VOLTAGE AT PCB

{SELHWCHON}

Next: !p2473, f2474

CH TEST LOCKOUT

{SELHWCHON}
APPLI

Next: p2479, f2480

HW TEST LOCKOUT

SELECTOR SWITCH TO H

Next: !p2483, !f2484

RESISTANCE OVERHEAT STAT AND HARNESS

UNPLUG CONNECTOR X401 FROM THE PCB

Next: p2494, f2491

RESISTANCE SENSOR TEMP DHW AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: p2495, f2496

RESISTANCE WATER PRESSURE SWITCH AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: p2499, f2500

INSPECTION ELECTRODES

REMOVE THE ELECTRODE ASSEMBLY FROM THE BOILER

Next: !p2823, !f2506

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: !p301, !f302

RESISTANCE WATER PRESSURE SWITCH

REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH

Next: !p2503, !f2504

GAS INLET PRESSURE

{SELHWCHON}
SET D

Next: p1751, !f537

INSPECTION DIVERTER VALVE DHW POSITION

SELECTOR SWITCH IN HOT WATER
REMOVE DIVERTER VALVE MOTOR

Next: p280, f281

RESISTANCE DHW FLOW SWITCH HARNESS

REMOVE CONNECTOR X400 FROM PCB AND CONNECTOR FROM THE HALL SENSOR ON THE FLOW SWITCH

Next: p2551, !f2552

INSPECTION FLOW SWITCH ASSEMBLY

ISOLATE MAINS WATER

Next: !p2553, !f2554

RESISTANCE SENSOR TEMP DHW AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: p2560, f2561

RESISTANCE WATER PRESSURE SWITCH AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: p2564, f2565

RESISTANCE OVERHEAT STAT AND HARNESS

UNPLUG CONNECTOR X401 FROM THE PCB

Next: p2570, f2571

RESISTANCE WATER PRESSURE SWITCH

REMOVE THE CONNECTOR FROM THE WATER PRESSURE SWITCH

Next: !p2568, !f2569

RESISTANCE FAN HARNESS AC

REMOVE THE 3 WIRE CONNECTOR FROM THE FAN ASSEMBLY
REMOVE CONNECTOR X2 FROM THE PCB

Next: p2574, !f2575

VOLTAGE AC TO FAN

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2576, !f2577

RESISTANCE FAN HARNESS

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB

Next: p2578, !f2579

VOLTAGE FAN SUPPLY

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p2580, !f2581

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: p259, !f260

VOLTAGE DC PCB SPEED REQUEST

Next: !p2582, !f2583

PUMP LIMPET TEST

Next: p2585, !f2586

TEMPERATURE DIFFERENTIAL DHW

ATTACH TEMPERATURE C

Next: !p2587, f2588

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: p2584, !f261

VOLTAGE FROM EXTERNAL CONTROLS

{SELHWCHON}
CH THERMOSTAT TO MAX

Next: p2854, !f2598

VOLTAGE FROM INTEGRAL TIMER / WIRELESS RECEIVER

{SELHWCHON}

Next: !p2599, ?2601, ?2603

VOLTAGE TO INTEGRAL TIMER / WIRELESS RECEIVER

{SELHWCHON}

Next: !p2607, !f2608

VOLTAGE LINKED CONNECTOR

{SELHWCHON}

Next: !p2605, !f2606

INSPECTION ORIFICE PLATE

SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD

Next: !p2610, !f2611

INSPECTION ORIFICE PLATE

SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD

Next: !p2613, !f2614

INSPECTION ORIFICE PLATE

SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD

Next: !p2616, !f2617

INSPECTION ORIFICE PLATE

SEPARATE THE FAN FROM THE AIR/GAS INLET MANIFOLD

Next: !p2619, !f2620

INSPECTION CONDENSATE PIPE

Next: p2175, !f2767

OPERATION DHW CONTROL KNOB/SPINDLE

GAIN ACCESS TO PCB

Next: !p2773, !f2774

OPERATION DHW CONTROL KNOB/SPINDLE

GAIN ACCESS TO PCB

Next: p250, !f2815

OPERATION DHW CONTROL KNOB/SPINDLE

GAIN ACCESS TO PCB

Next: p2621, !f2828

INSPECTION DIVERTER VALVE SPINDLE

REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY

Next: p286, !f287

OPERATION CH CONTROL KNOB/SPINDLE

GAIN ACCESS TO PCB

Next: p1014, !f2821

VOLTAGE AC SPARK GENERATOR

{SELHWCHON}
GAIN

Next: !p2826, !f2827

VOLTAGE MAINS IN AT PCB

Next: p2837, f2831

REMOVE DHW FLOW SWITCH DOES DISPLAY NOW WORK

REMOVE DHW HALL SENS

Next: p2838, !f2839

REMOVE CONNECTOR X400 DOES DISPLAY NOW WORK

REMOVE CONNECTOR X400 FROM PCB

Next: !p2840, !f2841

RESISTANCE SPARK GENERATOR AND HARNESS

REMOVE CONNECTOR X2 FROM THE PCB

Next: !p2843, f2844

RESISTANCE HARNESS EXTERNAL CONTROLS TO PCB

REMOVE CONNECTOR X3 FROM THE PCB

Next: p2597, !f2865

INSPECTION HEAT EXCHANGER DHW

DRAIN PRIMARY CIRCUIT OF BOILER DOWN
TURN OFF HW ISOLATION VALVE

Next: !p288, !f289

RESISTANCE HARNESS CONTROL PCB TO PUMP PCB

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p2870, !f2871

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: p2872, !f2873

VOLTAGE AC PUMP AT RELAY PCB

UNSCREW THE PUMP REL

Next: !p2874, !f2875

RESISTANCE HARNESS CONTROL PCB TO PUMP PCB

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p2879, !f2880

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: p2881, !f2882

VOLTAGE AC PUMP AT RELAY PCB

UNSCREW THE PUMP REL

Next: !p2883, !f2884

RESISTANCE HARNESS CONTROL PCB TO PUMP PCB

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p2888, !f2889

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: p2890, !f2891

VOLTAGE AC PUMP AT RELAY PCB

UNSCREW THE PUMP REL

Next: !p2892, !f2893

RESISTANCE HARNESS CONTROL PCB TO PUMP PCB

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p2901, !f2902

RESISTANCE HARNESS PUMP

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB
DISCONNECT THE PLUG FROM THE PUMP

Next: p2903, !f2904

VOLTAGE AC PUMP AT RELAY PCB

UNSCREW THE PUMP REL

Next: !p2905, !f2906

EXPANSION VESSEL PRESSURE

BOILER DISCHARGED

Next: !p370, !f371

INSPECTION DIVERTER VALVE POSITION CH

{SELHWCHON}
ALL HEATING CONTROLS CALLING
REMOVE DIVERTER VALVE MOTOR/ACTUATOR

Next: p391, f555

PUMP LIMPET TEST

Next: p397, !f398

BYPASS PIPE TEMPERATURE

{SELHWCHON}
USE T

Next: p399, !f400

INSPECTION RETURN FILTER

DRAIN BOILER HEATING CIRCUIT

Next: !p401, !f402

DOES PUMP RUN

Next: p443, f2876

PUMP LIMPET TEST

Next: p447, !f448

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: p449, !f529

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: p451, !f528

TEMPERATURE DIFFERENTIAL DHW

ATTACH TEMPERATURE C

Next: p2021, f454

CH TEST OVERHEAT

{SELHWCHON}
APPLI

Next: !p462, ?466, ?468

RESISTANCE DIVERTER HARNESS

REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR

Next: !p558, !f559

RESISTANCE DIVERTER HARNESS

REMOVE CONNECTOR X3 FROM PCB
REMOVE DIVERTER HEAD FROM ITS CONNECTOR

Next: !p564, !f565

RESISTANCE WATER PRESSURE SWITCH AND HARNESS

REMOVE THE PLUG X400 FROM THE PCB

Next: !p611, f612

DOES PUMP RUN

Next: p643, f2885

PUMP LIMPET TEST

Next: p649, !f650

RESISTANCE SENSOR TEMP PRIMARY

DISCONNECT THE INLINE CONNECTOR TO THE PRIMARY SENSOR

Next: p651, !f652

RESISTANCE SENSOR TEMP DHW

REMOVE THE LEAD FROM THE DHW SENSOR

Next: p2478, !f654

RESISTANCE FAN HARNESS

REMOVE THE 4 WIRE CONNECTOR FROM THE FAN
REMOVE CONNECTOR X401 FROM THE PCB

Next: p797, !f795

VOLTAGE AC TO FAN

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p1551, !f794

VOLTAGE FAN SUPPLY

GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)

Next: p798, !f799

VOLTAGE DC FROM FAN

{SELHWCHON}

Next: p1524, !f804

RESISTANCE PUMP AND HARNESS

DISCONNECT CONNECTOR X1 FROM THE PUMP PCB

Next: p811, f812

RESISTANCE FAN AND HARNESS DC

DISCONNECT CONNECTOR X401 FROM THE PCB

Next: p815, f816

RESISTANCE FAN AND HARNESS AC

REMOVE CONNECTOR X2 FROM THE PCB

Next: p819, f820

RESISTANCE DIVERTER VALVE AND HARNESS

REMOVE CONNECTOR X3 FROM THE PCB
REMOVE DIVERTER VALVE HEAD FROM BODY

Next: p2842, f824

INSPECTION FLOW SWITCH ASSEMBLY

ISOLATE MAINS WATER

Next: !p99, !f1308

System Information

  • Total Tests: 640
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control