Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB (use insulation mat as required)
Gain access to PCB (use insulation mat as required)
Measurement:
Remove the plug-on connector marked CON 1 FLOW SWITCH (black wires) on PCB 27.
Measure the resistance across the connector (NOT the pins on the PCB).
Replace plug after test.
Measure the resistance across the connector (NOT the pins on the PCB).
Replace plug after test.

Isolate as per TOPs P4
and refit as necessary