Set Appliance State:
Mains Power Off
Gas Off
Ensure DHW is cool (this can be achieved by running the DHW with the gas to the appliance turned off)
Disconnect plug from DHW temperature sensor (orange wires)
Disconnect plug from DHW temperature sensor (orange wires)
Measurement:
Measure resistance across the exposed terminals of the DHW sensor.
Note: Expected reading with water temperature at 18 degrees C would be approximately 13 kOhms
Note: Expected reading with water temperature at 18 degrees C would be approximately 13 kOhms

Isolate as per TOPs P4
and refit as necessary