Set Appliance State:
Mains Power Off
Gas Off
Turn Hot Water Tap On
Set flow rate at tap to approximately 7 ltr/min
Gas On
Mains Power On
Measurement:
Allow boiler to fire and heat DHW to approximately 55 degrees C.
Turn off hot tap.
Mains power OFF.
Disconnect plug from DHW temperature sensor (orange wires).
Measure resistance across the exposed terminals of the DHW temperature sensor.
Replace plug after test.
Turn off hot tap.
Mains power OFF.
Disconnect plug from DHW temperature sensor (orange wires).
Measure resistance across the exposed terminals of the DHW temperature sensor.
Replace plug after test.

Isolate as per TOPs P4
and refit as necessary