Set Appliance State:
Mains Power Off
Gas Off
Boiler disconnected from mains supply.
Measurement:
Warning - Important Notice:
The information contained within this application is for the use by and guidance of engineers, who have been trained in gas installation and/or gas service practice. Individuals must apply safe working practices in accordance with their training, while taking due regard of company procedures, when undertaking any type of work.
Ensure all basic electrical safety checks are carried out, including the following;
i. Check earth continuity
ii. Short circuit
iii. Polarity
The information contained within this application is for the use by and guidance of engineers, who have been trained in gas installation and/or gas service practice. Individuals must apply safe working practices in accordance with their training, while taking due regard of company procedures, when undertaking any type of work.
Ensure all basic electrical safety checks are carried out, including the following;
i. Check earth continuity
ii. Short circuit
iii. Polarity
Isolate as per TOPs P4
and refit as necessary