Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect connector X7 from the PCB
Disconnect connector X7 from the PCB
Measurement:
Test 1.
Measure the resistance between pin 4.1 (green) and
pin 4.4 (blue) on connector X7.
Test 2.
Measure the resistance between pin 4.2 (red) and
pin 4.3 (black) on connector X7.
Expect approx. 24 Ohms on both tests.
Measure the resistance between pin 4.1 (green) and
pin 4.4 (blue) on connector X7.
Test 2.
Measure the resistance between pin 4.2 (red) and
pin 4.3 (black) on connector X7.
Expect approx. 24 Ohms on both tests.

Isolate as per TOPs P4