Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect connector X6 from the PCB
Disconnect connector X6 from the PCB
Measurement:
Measure the resistance between the white wires on X6, marked 16.1 and 16.2.
The resistance should conform approximately to the table below:
The resistance should conform approximately to the table below:

Isolate as per TOPs P4
and refit as necessary