Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove CN2 from the PCB

Measurement:

Measure the resistance between pins 6 and 5 on connector CN2.
Resistance should be 790Ω
Measure the resistance between pin 6 on
connector CN2 to a suitable earth point.
Resistance should be greater than 1MΩ (Or O.L.)