Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove power electrical connector from fan assembly
Removing side panel from appliance will make this test considerably easier to carry out
Removing side panel from appliance will make this test considerably easier to carry out
Measurement:
Test 1.
Measure for resistance across pins 1 and 3 of fan connection.
Expected resistance greater than 1MΩ (or O.L)
Test 2.
Measure for resistance across pin 1 and 2 fan connection.
Expected resistance greater than 1MΩ (or O.L)
Measure for resistance across pins 1 and 3 of fan connection.
Expected resistance greater than 1MΩ (or O.L)
Test 2.
Measure for resistance across pin 1 and 2 fan connection.
Expected resistance greater than 1MΩ (or O.L)

Isolate as per TOPs P4
and refit as necessary