Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Cancel purge cycle & If required, reset boiler.
Allow the boiler to operate for DHW.
Measure the A/C voltage across the bottom pins
(black and blue) of connector CN4.
Mains voltage should be present.