Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X6 from the PCB
Measurement:
Test 1:
Measure the resistance between pin 6 (brown) and
pin 7 (blue) wires on X6 connector.
Resistance should be approximately 7.8kOhms.
Test 2:
Measure the resistance between pin 6 (brown)
on X6 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 7 (blue)
on X6 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between pin 6 (brown) and
pin 7 (blue) wires on X6 connector.
Resistance should be approximately 7.8kOhms.
Test 2:
Measure the resistance between pin 6 (brown)
on X6 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 7 (blue)
on X6 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary