Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
Use Insulation Mat as required
Selector switch to hot water
DHW Temperature selector to maximum
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the voltage across the red (Note: there are two red wires, the red wire for this test is located between the black wire and white wire) and white wires on J6 (black connector) on main pcb.
0V DC should be measured.
Turn hot water tap On.
Repeat test.
5V DC should be measured.
Note:
For these tests it is easiest to connect the probes to the front of the connector where exposed silver connections can be seen,