Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector J6 from main PCB

Measurement:


Measure the resistance across the red wire (Note: use the red wire on the far left) and the black wire at the disconnected connector J6 (black connector).
The resistance will depend upon the temperature of the boiler the hotter the boiler the lower the resistance. The resistance should conform to the table below.

Temperature°C

Resistance kOhms

20-2511.4-12.5
25-309.7-11.4
30-357.5-9.7
35-406.5-7.5
40-505.0-7.2
50-603.0-5.0
60-702.5-3.0
70-801.8-2.5
80-901.3-1.8