Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove the green plug from the sensor

Measurement:


Measure the resistance across the exposed terminals of the sensor.
The resistance will depend upon the temperature of the boiler the hotter the boiler the lower the resistance. The resistance should conform to the table below:

Temperature °C

Resistance kOhms

20-2511.4-12.5
25-309.7-11.4
30-357.5-9.7
35-406.5-7.5
40-505.0-7.2
50-603.0-5.0
60-702.5-3.0
70-801.8-2.5
80-901.3-1.8