Set Appliance State:

Mains Power Off
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Use Insulation Mat as required
Selector switch to hot water
DHW temperature selector to maximum
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Ensure the boiler is not in lockout. Take the following measurements
when sparking commences.
Test 1
Measure the voltage across the brown and blue wires at connector
J3 (black) on the ignition pcb.
Test 2
Measure the voltage across the black and blue wires at connector
J3 (black) on the ignition pcb.
Note:
The boiler will go to lockout if it does not ignite and will need resetting.