Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the 12 way connector from the front of the PCB
Remove the 12 way connector from the front of the PCB
Measurement:
Test 1:
Measure the resistance between pin 1 (black) and
pin 2 (blue) on the 12 way connector.
Expected resistance approximately 4 kOhms.
Test 2:
Measure the resistance between pin 1 (black) and a suitable earth.
Expect a resistance of 1 MOhm or greater.
Measure the resistance between pin 1 (black) and
pin 2 (blue) on the 12 way connector.
Expected resistance approximately 4 kOhms.
Test 2:
Measure the resistance between pin 1 (black) and a suitable earth.
Expect a resistance of 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary