Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Gain access to bottom of PCB
(This may require unclipping from main bracket)
Remove the fan connector from the PCB
Note:
Ensure PCB is located safely before turning the power back ON
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between terminal 4 (the blue wire location when plug is fitted) of the PCB fan connector and a suitable earth. The fan connection is at the bottom left hand side of the PCB.
Expect a voltage of approximately 75 vdc 5 seconds after power is reinstated as the PCB attempts to send power to the fan.
Note:
Shortly before the fault code is shown the voltage will increase to 110 vdc, reset the boiler as necessary until the result of the test can be ascertained.