Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Connect the air pressure switch charge kit to +ve connection on the air pressure switch, disconnect the -ve connection and ensure performance tester reads 0mb before continuing
Selector Switch in Hot Water Position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Note the operating pressure indicated on the pressure switch.
Allow the boiler to begin it's ignition sequence.
Approximately 2 seconds after the fan starts
to run increase the pressure via the syringe
to that indicated on the pressure switch.
Can sparking now be observed
between the ignition electrodes?
Note:
100Pa (Pascals) = 1millibar
If sparking is not observed it is permissible to increase the pressure by up to 50%