Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Set flow rate to 2.8 litres a minute
Selector Switch in Hot Water Position
Gain access to PCB (use insulation mat as necessary)
Selector Switch in Hot Water Position
Gain access to PCB (use insulation mat as necessary)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for mains voltage between the brown wire marked 3
and the blue wire marked 1 on connector X3 at the PCB.
and the blue wire marked 1 on connector X3 at the PCB.