Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Remove the gas valve connectors from the gas valve
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance (press and hold reset button for 5 seconds, then release).
Measure voltage at both of the disconnected gas valve connectors.
Approximately 38 volts DC should be measured at both locations.
Notes:
1. Take care not to short the connections.
2. There are different versions of this appliance, connections to the gas valve can be 2 x purple leads or blue and purple leads.
3. Lockout will occur after 5 attempts to ignite, reset as required until test complete.