Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Voltage Set meter to measure AC Volts
Turn Hot Water Tap On
Attach Red Crocodile Clip to the Red Wire on the Fan
Attach Black Crocodile Clip to the White Wire on the Fan
Selector Switch in DHW Position
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the Potential Difference between the Red and White Wires at the Fan Assembly
A constant voltage reading of 35V AC or Greater is expected.
Warning Voltages at the Fan can be up to 310V AC