Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect leads from the air pressure switch noting the connections

Measurement:

Note the operating pressure indicated on the pressure switch.
Connect the air pressure switch charge kit to +ve connection on the air pressure switch.
Increase the pressure via the syringe to that indicated on the pressure switch. Continuity (zero resistance) should then be measured between common and normally open terminals on the air pressure switch.
Note:
35 CDi II appliances may have APS fitted
inside combustion chamber next to fan.
If continuity is not obtained it is permissible to
increase the pressure by 50%.
100 Pascals = 1mbar / 50 Pascals = 0.5mbar