Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove inner casing panel
Observation:
Thoroughly check the spark electrodes for signs of damage, cracked ceramic insulation or shorting.
Check the spark electrodes are properly secured to the burner, also check that the spark gap between the electrodes is approximately 4mm apart and 4mm above the burner.
Check the spark electrodes are properly secured to the burner, also check that the spark gap between the electrodes is approximately 4mm apart and 4mm above the burner.
Isolate as per TOPs P4
and refit as necessary