Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X6 from the PCB
Measurement:
Test 1:
With hot tap fully open measure the resistance across pins 1 & 2 of connector X6.
Resistance should read short circuit.
Test 2:
Turn off the DHW tap and repeat the test.
Resistance should read open circuit.
With hot tap fully open measure the resistance across pins 1 & 2 of connector X6.
Resistance should read short circuit.
Test 2:
Turn off the DHW tap and repeat the test.
Resistance should read open circuit.

Isolate as per TOPs P4
and refit as necessary