Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Reset the overheat thermostat by pushing in the button underneath the boiler.
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary.
Now the overheat has been reset does the boiler ignite and establish correctly?
Please select from the options below:
Overheat resets and burner ignites and establishes - Investigate causes of overheat
Overheat resets but burner still does not ignite and establish
Overheat button will not push in - Replace overheat thermostat
Now the overheat has been reset does the boiler ignite and establish correctly?
Please select from the options below:
Overheat resets and burner ignites and establishes - Investigate causes of overheat
Overheat resets but burner still does not ignite and establish
Overheat button will not push in - Replace overheat thermostat