Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Remove lower facia panel
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across connection CI on connector block X2 and the neutral (marked N) on connector block X1. Both connector blocks are situated at the bottom L/H side of the PCB.
Note:
If no programmer is fitted a link will be present between "Cl" and "CL".
Note:
If no programmer is fitted a link will be present between "Cl" and "CL".

Isolate as per TOPs P4
and refit as necessary