Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn hot water tap on
Boiler On/Off switch On
Attach pressure gauge to gas valve outlet pressure test point
Remove connector from the modulating solenoid (blue wires)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset lockout if necessary.
Allow boiler to commence its ignition sequence and ignite.
Observe the pressure gauge, does the burner run at low gas pressure (approximately 1.8mb)?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.