Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Programmer or selector switch set to hot water only
Heating temperature selector to OFF
Hot water temperature selector to mid-range
Programmer or selector switch set to hot water only
Heating temperature selector to OFF
Hot water temperature selector to mid-range
Gas On; Pilot On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across connection 3 (pink wire) on connector X2 and connection 3 (neutral, blue wire) on connector X11 on the PCB.
Note:
Expected temperature of heatbank is:-
Min (1) 57 degrees C - approximately 7 minutes
Mid (3) 65 degrees C - approximately 10 minutes
Max (5) 70 degrees C - approximately 15 minutes
Temperature taken with temperature probe/thermometer between heatbank and its insulation near thermostat pocket.
Note:
Expected temperature of heatbank is:-
Min (1) 57 degrees C - approximately 7 minutes
Mid (3) 65 degrees C - approximately 10 minutes
Max (5) 70 degrees C - approximately 15 minutes
Temperature taken with temperature probe/thermometer between heatbank and its insulation near thermostat pocket.

Isolate as per TOPs P4
and refit as necessary