Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Heating temperature selector to OFF
Programmer or selector switch set to hot water only
Hot water temperature selector to maximum
Heating temperature selector to OFF
Programmer or selector switch set to hot water only
Hot water temperature selector to maximum
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure voltage across connection 3 (brown wire) and connection 2 (blue wire) at connector X7 on the main PCB.
With no CH demand there should be no voltage present.
With no CH demand there should be no voltage present.

Isolate as per TOPs P4
and refit as necessary