Set Appliance State:

Mains Power Off
Set Multimeter to Resistance Set meter to measure resistance
Heating temperature selector to OFF
Hot water temperature selector to mid-range
Ensure heatbank is not up to temperature (this can be achieved by running the DHW with the mains power to the appliance on and the pilot switched off)
Gas On; Pilot On
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow boiler to heat the heatbank to approximately 70 degrees C.
Isolate Mains Power to appliance as per TOPs P4

Remove one of the pink wires (1) from the DHW thermostat.
Measure the resistance across the thermostat terminals.
Replace wire after test.