Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN7 from the PCB
Disconnect AC connector (3 wire) from the fan
Disconnect AC connector (3 wire) from the fan
Measurement:
Test 1:
Measure the resistance between pin 1 (Brown)
on the fan connector and pin 49 (Brown) on connector CN7.
Test 2:
Measure the resistance between pin 3 (Blue)
on the fan connector and pin 48 (Blue) on connector CN7.
Test 3:
Measure the resistance between pin 2 (Earth)
on the fan connector and the boiler chassis.
Expect continuity/zero resistance on each of the above tests.
Also visually inspect the condition of the harness.
Measure the resistance between pin 1 (Brown)
on the fan connector and pin 49 (Brown) on connector CN7.
Test 2:
Measure the resistance between pin 3 (Blue)
on the fan connector and pin 48 (Blue) on connector CN7.
Test 3:
Measure the resistance between pin 2 (Earth)
on the fan connector and the boiler chassis.
Expect continuity/zero resistance on each of the above tests.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary