Set Appliance State:
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Cancel purge cycle.
Access parameter B03
Click HERE for guidance on how to access the parameters.
Check parameter B03, this is the system water pressure protection, this can change if the appliance experiences electrical supply fluctuations and can also be set incorrectly after a replacement PCB has been fitted.
The required parameter setting is dependent upon the PCB software version, the software version will appear on the display when the appliance is turned on.
For the correct parameter values, click HERE to return to ADAPT and refer to the software version tables, usually located in the 'other' section.
Note.
This appliance is fitted with a water pressure switch.
Access parameter B03
Click HERE for guidance on how to access the parameters.
Check parameter B03, this is the system water pressure protection, this can change if the appliance experiences electrical supply fluctuations and can also be set incorrectly after a replacement PCB has been fitted.
The required parameter setting is dependent upon the PCB software version, the software version will appear on the display when the appliance is turned on.
For the correct parameter values, click HERE to return to ADAPT and refer to the software version tables, usually located in the 'other' section.
Note.
This appliance is fitted with a water pressure switch.