Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove burner

Observation:

Inspect burner for damage and good general condition.
If the burner is satisfactory do not refit it at this stage.
Note:
Before the burner is refitted and the appliance left in operation the gasket MUST be replaced.