Set Appliance State:
Turn Hot Water Tap On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary.
Allow the appliance to run with a DHW demand for 4 minutes.
Does the burner remain alight or does it drop out during operation?
Does fault code A06 re appear?
Note:
A06 fault code appears when the burner has lit and rectified but then drops out during operation, this is not temperature related but is when the PCB loses the flame rectification during operation 6 times in 4 minutes, for instance if the burner baffles out.
Allow the appliance to run with a DHW demand for 4 minutes.
Does the burner remain alight or does it drop out during operation?
Does fault code A06 re appear?
Note:
A06 fault code appears when the burner has lit and rectified but then drops out during operation, this is not temperature related but is when the PCB loses the flame rectification during operation 6 times in 4 minutes, for instance if the burner baffles out.