Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Using a crocodile clip attach the ignition lead so the end is just above the spark generator terminal as shown
(no greater than 4mm away)
Using a crocodile clip attach the ignition lead so the end is just above the spark generator terminal as shown
(no greater than 4mm away)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance lockout as necessary, allow fan purge to complete (2 minutes), allow the fan to run and the ignition sequence to commence.
Is there a strong consistent spark between the spark generators terminal and the end of the ignition lead?
Notes:
1. The ignition lead may differ in appearance but the test is carried out in the same way.
2. The appliance may lockout during this test reset as necessary to complete the test.
Is there a strong consistent spark between the spark generators terminal and the end of the ignition lead?
Notes:
1. The ignition lead may differ in appearance but the test is carried out in the same way.
2. The appliance may lockout during this test reset as necessary to complete the test.