Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove connector X3 from the PCB
Remove connector X3 from the PCB
Measurement:
Test 1:
Measure the resistance between the two wires on connector X3.
Expect a resistance of approximately 180 ohms or greater.
Test 2:
Measure between one of the wires on connector X3 and a suitable earth.
Expect a resistance of 1 MOhm or greater.
Are the resistances measured as expected?
Measure the resistance between the two wires on connector X3.
Expect a resistance of approximately 180 ohms or greater.
Test 2:
Measure between one of the wires on connector X3 and a suitable earth.
Expect a resistance of 1 MOhm or greater.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary