Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
External controls calling for heat
CH temperature switch to minimum
DHW temperature switch to maximum
Gain access to PCB (use insulation mat as required)
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the voltage at connection 1 (red wire) and connection 2 (purple wire) on connector X6 on the PCB.
Expected voltage approximately 43 volts DC.