Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove cover from pump assembly
Remove cover from pump assembly
Measurement:
Test 1:
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 180 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Expect a resistance of 1 MOhm or greater.
Are the resistances measured as expected?
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 180 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Expect a resistance of 1 MOhm or greater.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary