Set Appliance State:
Mains Power Off
Ensure selector switch is set to DHW/CH position.
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC voltage across test point 1 & 3.
Expected voltage approximately 4.6 Vdc.
Note.
Ensure a good connection is made as misdiagnosis will occur.
Expected voltage approximately 4.6 Vdc.
Note.
Ensure a good connection is made as misdiagnosis will occur.

Isolate as per TOPs P4
and refit as necessary