Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Set selector switch to the OFF position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1. Measure for DC voltage across the two reds leads of connector X16.
Expected voltage 39 Vdc (may be a positive or negative voltage).
Test 2. Set selector switch from the OFF position to the DHW/CH position.
Allow boiler to commence its ignition sequence (fan running).
Measure for DC voltage at the same location as test 1.
Expected voltage 0 Vdc.