Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Attach pressure gauge to gas valve inlet pressure test point
Ensure NO other gas appliances are in operation
NO demands present
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset appliance if required (Press reset button once then release)
Allow the appliance to complete its self-check.
Run the appliance in test function (MAX output) and allow the burner to ignite and establish.
CLICK HERE FOR GUIDANCE ON HOW TO ACTIVATE TEST FUNCTION
Observe the Pressure gauge and cancel the test function to extinguish the flame (Press Reset button to cancel function)
As soon as the demand ceases the gauge should return to standing pressure immediately.