Next: &nff, !f1436
DHW SERVICE VALVE
Next: End
SYSTEM PRESSURE
Next: End
WIRING HARNESS (TR2)
Next: End
HANDLES - ROTARY (CH)
Next: End
WIRING HARNESS (TR2)
Next: End
SYSTEM PRESSURE
Next: End
SYSTEM PRESSURE
Next: End
SYSTEM PRESSURE
Next: End
SENSOR - NTC FLOW
Next: End
SENSOR - TEMPERATURE
Next: End
HARNESS - PCB TO DISPLAY
Next: End
WIRING HARNESS (TR2)
Next: End
LEAD - HT - IGNITION
Next: End
PLATE - BEARING
Next: End
DIRECTION CHOICE OR CONTINUE
Next: End
SYSTEM PRESSURE
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
SENSOR - TEMPERATURE
Next: End
GAS INLET PRESSURE
Next: End
ELECTRODES - SET OF 3
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
HARNESS - PCB TO DISPLAY
Next: End
SENSOR - NTC FLOW
Next: End
GAS INLET PRESSURE
Next: End
PLATE - BEARING
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
INTEGRAL PROGRAMMER / MODULE
Next: End
HANDLES - ROTARY (CH)
Next: End
ELECTRICAL SAFETY CHECKS
Next: End
SENSOR - NTC FLOW
Next: End
SENSOR - NTC FLOW
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - NTC FLOW
Next: End
GAS INLET PRESSURE
Next: End
SENSOR - TEMPERATURE
Next: End
MICROSWITCH N/C
Next: End
PACK - 10 OFF FUSE 5A 20MM - T2
Next: End
MICROSWITCH N/C
Next: End
SENSOR - TEMPERATURE
Next: End
EXPANSION VESSEL
Next: End
SENSOR - TEMPERATURE
Next: End
STRAINER - WATER
Next: End
SENSOR - TEMPERATURE
Next: End
HANDLES - ROTARY (DHW)
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - NTC FLOW
Next: End
SENSOR - TEMPERATURE
Next: End
SENSOR - NTC FLOW
Next: End
DIRECTION CHOICE OR CONTINUE
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
PCB AND LEAD - HT- IGNITION
Next: End
PCB AND LEAD - HT- IGNITION
Next: End
MAINS WATER PRESSURE
Next: End
PLATE - BEARING
Next: End
LEAD - HT - IGNITION
Next: End
PLATE - BEARING
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
SENSOR - NTC FLOW
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
PLATE - BEARING (FAN SPEED)
Next: End
SENSOR - TEMPERATURE
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
PCB WATER INGRESS
Next: End
ELECTRODES - SET OF 3
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
PCB AND ELECTRODE ASSEMBLY
Next: End
FAULT CODE RESET
Next: End
CONTROL - ROOM TEMPERATURE
Next: End
DIVERTER VALVE - 3 WAY (CH)
Next: End
FAULT CODE RESET (A8)
Next: End
CONTROL - ROOM TEMPERATURE
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
PUMP VARIABLE SPEED
Next: End
TEMPERATURE LIMITER ASSEMBLY
Next: End
INTEGRAL PROGRAMMER / MODULE
Next: End
DIVERTER VALVE - 3 WAY
Next: End
MOTOR - DIVERTER VALVE
Next: End
MOTOR - DIVERTER VALVE
Next: End
INTEGRAL PROGRAMMER / MODULE
Next: End
GAS INLET PRESSURE
Next: End
ELECTRODES - SET OF 3
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
DIRECTION CHOICE OR CONTINUE
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
FAULT CODE RESET
Next: End
CHARACTERISTIC TEST FROM OBSERVATION RUN TO MAX TEMP - OVERHEAT OCCUR
Next: p1299
CHARACTERISTIC TEST FROM OBSERVATION RUN TO MAX TEMP - OVERHEAT OCCUR
Next: p1336
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
Next: p1377
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p191
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p1178
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p195
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p197
CHARACTERISTIC TEST FROM CH OPERATION
Next: p205
CHARACTERISTIC TEST FROM CH OPERATION
Next: p207
CHARACTERISTIC TEST FROM DHW OPERATION
Next: p269
CHARACTERISTIC TEST FROM CH OPERATION
Next: p358
CHARACTERISTIC TEST FROM CH OPERATION
Next: p376
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
Next: p768
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
Next: p770
CHARACTERISTIC TEST FROM ? MODE OF FAN OPERATION
Next: p773
CHARACTERISTIC TEST FROM SPARKING ELECTRODE LEADS
Next: p786
CHARACTERISTIC TEST FROM SPARKING ELECTRODE LEADS
Next: p788
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
Next: p796
CHARACTERISTIC TEST FROM PRESSURE GAS INLET DROP
Next: !p798
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE ASSEMBLY
Next: !p828
CHARACTERISTIC TEST FROM INSPECTION BURNER AND ELECTRODE ASSEMBLY
Next: !p830
CHARACTERISTIC TEST FROM ? MODE OF FAN OPERATION
Next: p849
CHARACTERISTIC TEST FROM ? MODE OF FAN OPERATION
Next: p859
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p864
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p866
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p947
CHARACTERISTIC TEST FROM FAN VOLTAGE CONTROL (PCB)
Next: p949
16/12/2020 10:16:53
Next: End
{GAINPCBACS}
Next: p1042, f1047
REMOVE FUSE F3 FROM ITS HOLDER
Next: p1048, !f1049
GAIN ACCESS TO WIRING CONNECTIONS FOR THE
TR2 ROOM STAT AND PROGRAMMER PCB
Next: !p1082, !f1080
{GAINPCBACS}
Next: p1100, f1097
{GAINPCBACS}
Next: !p1098, !f1099
{GAINPCBACS}
Next: p1125, f1139
{GAINPCBACS}
Next: p1157, f1158
{GAINPCBACS}
Next: !p1172, !f1173
{GAINPCBACS}
Next: !p1213, !f1214
{GAINPCBACS}
Next: !p1218, !f1219
{GAINPCBACS}
Next: !p1221, !f1222
{GAINPCBACS}
Next: !p1224, !f1225
DISCONNECT THE WIRING HARNESS BETWEEN THE MAIN PCB AND THE TIMER MODULE
Next: p1227, !f1228
{GAINPCBACS}
Next: p1236, !f1237
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
CH THERMOSTAT TO MAX
Next: !p1259, !f1260
{GAINPCBACS}
Next: !p1286, !f1287
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
CH THERMOSTAT TO MAX
Next: !p1308, !f1342
{GAINPCBACS}
Next: p1275, f1276
{GAINPCBACS}
Next: !p1284, !f1285
ATTACH U-GAUGE TO THE INLET PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR TO HIGH SETTING
Next: p1347, !f1348
REMOVE THE DISPLAY FROM THE FACIA
REMOVE CONNECTOR ST5 FROM THE PCB
Next: p1369, !f1370
DHW INLET VALVE OFF
DHW DISCHARGED AND DRAINED
Next: p23, !f24
{GAINPCBACS}
Next: p1412, f1413
{GAINPCBACS}
Next: !p1414, !f1415
ENSURE GAS IS TURNED OFF AT THE INLET OF THE APPLIANCE
Next: p228, !f229
{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE AND MAKE SAFE
Next: p453, !f257
{GAINPCBACS}
REMO
Next: p459, f290
DHW INLET VALVE OFF
DISCONNECT CONNECTOR PLUG MARKED ST 16 FROM THE PCB
Next: !p327, !f328
DHW INLET VALVE OFF
DISCONNECT CONNECTOR PLUG MARKED ST 16 FROM THE PCB
Next: p292, !f293
{GAINPCBACS}
BOILER ON/OFF SWITCH ON
Next: p296, f297
REMOVE FUSE F1 FROM ITS HOLDER
Next: p298, !f299
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: !p369, !f370
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
CH THERMOSTAT TO MAX
Next: !p1205, !f1204
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p497, !f498
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p512, !f513
DISCONNECT RED LEADS FROM THE OH THERMOSTAT
Next: p777, !f778
REMOVE THE FLAME SEN
Next: !p833, !f834
DISCONNECT CONNECTOR PLUG MARKED ST 16 FROM THE PCB
Next: p902, f903
REMOVE PLUG CONNECTI
Next: !p906, !f907
BOILER ON/OFF SWITCH OFF
DHW TEMPERATURE SELECTOR TO HIGH SETTING
Next: p918, f943
BOILER ON/OFF SWITCH
Next: !p962, f944
BOILER ON/OFF SWITCH
Next: p945, ?946, ?948
BOILER ON/OFF SWITCH OFF
Next: p965, !f966
DISCONNECT CONNECTOR PLUG MARKED ST 16 FROM THE PCB
Next: p971, f972
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: !p973, !f974
REMOVE CONNECTOR MARKED ST16 FROM PCB
Next: p986, f981
DISCONNECT RED LEADS FROM THE OH THERMOSTAT
Next: p982, !f983
REMOVE TRANSFORMER F
Next: !p1050, !f1051
LOCATE TR2 ROOM STAT
Next: !p1084, f1077
BOILER ON/OFF SWITCH
Next: p1405, f1411
GAIN ACCESS TO WIRING CONNECTIONS FOR THE
TR2 ROOM STAT AND PROGRAMMER PCB
Next: !p1111, !f1112
{GAINPCBACS}
REMOVE THE DC PUMP CONNECTOR FROM THE PCB AND MAKE SAFE
Next: p1358, f1127
{GAINPCBACS}
REMOVE THE DC PUMP CONNECTOR FROM THE PCB AND MAKE SAFE
Next: p1361, f1162
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p1211, !f1212
ATTACH TEMPERATURE P
Next: !p1215, f1258
GAIN ACCESS TO WIRING CONNECTIONS FOR THE
TR2 ROOM STAT AND PROGRAMMER PCB
Next: p1229, !f1230
DISCONNECT ELECTRODE LEADS
Next: p1238, !f1239
REMOVE THE FLAME SEN
Next: p1240, !f1241
REMOVE AIR INTAKE HO
Next: p1251, !f1257
REMOVE THE FRONT COVER FROM THE HEAT EXCHANGER
Next: !p1253, !f1256
ATTACH TEMPERATURE P
Next: p1309, f1271
ATTACH TEMPERATURE P
Next: !p1434, ?1292, ?1333
{GAINPCBACS}
REMOVE THE DC PUMP CONNECTOR FROM THE PCB AND MAKE SAFE
Next: p1364, f1280
DISCONNECT RED LEADS FROM THE OH THERMOSTAT
Next: !p1306, !f1301
ATTACH TEMPERATURE PROBES AS INDICATED BY THE RED ARROWS
CH THERMOSTAT TO MAX
Next: p1418, f1343
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: !p1337, !f1338
DISCONNECT PUMP PLUGS FROM PCB
Next: !p1359, !f1360
DISCONNECT PUMP PLUGS FROM PCB
Next: !p1362, !f1363
DISCONNECT PUMP PLUGS FROM PCB
Next: !p1365, !f1366
DISCONNECT THE HARNESS BETWEEN THE PCB AND THE DISPLAY
Next: !p1371, !f1372
DISCONNECT CONNECTOR PLUG MARKED ST 16 FROM THE PCB
Next: !p1374, !f1375
ATTACH U-GAUGE TO THE INLET PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR TO HIGH SETTING
Next: p1382, !f1381
ATTACH F.G.A UNIT TO FAN PRESSURE TEST POINT
Next: p1383, f1384
REMOVE THE FRONT COVER FROM THE HEAT EXCHANGER
Next: p1387, !f1388
REMOVE AIR INTAKE HO
Next: !p1389, !f1390
BOILER ON/OFF SWITCH OFF
Next: p1395, !f1394
REMOVE AIR INTAKE HO
Next: p993, !f1404
CENTRAL HEATING THER
Next: p1110, !f1409
DHW TEMPERATURE SELECTOR TO HIGH SETTING
Next: p224, f225
REMOVE DIVERTER VALV
Next: !p452, f251
REMOVE PLUG CONNECTI
Next: p262, !f263
BOILER CH THERMOSTAT
Next: !p1083, f285
ATTACH U-GAUGE TO THE INLET PRESSURE TEST POINT
DHW TEMPERATURE SELECTOR TO HIGH SETTING
Next: p236, !f278
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p230, !f279
DHW INLET VALVE OFF
DHW DISCHARGED AND DRAINED
Next: !p25, !f26
REMOVE PLUG CONNECTI
Next: !p232, !f233
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p264, !f265
DHW INLET VALVE OFF
DHW DISCHARGED AND DRAINED
Next: !p266, !f267
REMOVE PLUG CONNECTI
Next: p1209, !f1210
{GAINPCBACS}
Next: p294, f295
REMOVE FUSE F2 FROM ITS HOLDER
Next: p306, !f307
REMOVE FUSE F3 FROM ITS HOLDER
Next: p302, !f303
{GAINPCBACS}
Next: !p300, !f301
REMOVE TRANSFORMER F
Next: !p304, !f305
BOILER ON/OFF SWITCH OFF
Next: p478, !f309
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: p361, !f362
WATER INLET SERVICE
Next: !p373, !f374
REMOVE THE ORANGE LEADS FROM THE PRIMARY SENSOR
Next: !p377, !f378
ATTACH TEMPERATURE P
Next: !p1201, f398
REMOVE THE DIVERTER
Next: !p455, !f454
REMOVE THE DIVERTER
Next: !p460, !f461
BOILER ON/OFF SWITCH OFF
REMOVE AND DISCONNECT INTERNAL PROGRAMMER
Next: !p510, f511
REMOVE PLUG CONNECTI
Next: p499, !f500
BOILER ON/OFF SWITCH OFF
DISCONNECT FAN CONNECTOR FROM THE PCB
Next: p503, !f504
ON/OFF SWITCH OFF
Next: p505, !f506
REMOVE PLUG CONNECTI
Next: p514, !f515
BOILER ON/OFF SWITCH OFF
DISCONNECT FAN CONNECTOR FROM THE PCB
Next: p518, !f519
ON/OFF SWITCH OFF
Next: p520, !f521
DHW INLET VALVE IS L
Next: p15, !f10
DHW TEMPERATURE SELECTOR TO HIGH SETTING
BOILER ON/OFF SWITCH OFF
Next: p831, f832
Next: p771, ?772, ?848, ?858
REMOVE CONNECTOR MARKED ST16 FROM PCB
Next: p1373, f776
REMOVE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p779, !f780
BOILER ON/OFF SWITCH
Next: p783, ?785, ?787
ATTACH U GAUGE TO INLET PRESSURE TEST POINT OF THE GAS VALVE
Next: p793, ?795, ?797
DISCONNECT ELECTRODE LEADS
Next: !p791, !f792
DISCONNECT ELECTRODE LEADS
Next: !p789, !f790
DISCONNECT ELECTRODE LEADS
Next: p813, !f814
DISCONNECT THE PLUG
Next: p799, !f800
ATTACH F.G.A UNIT TO FAN PRESSURE TEST POINT
Next: p801, f802
REMOVE THE FRONT COVER FROM THE HEAT EXCHANGER
Next: p805, !f806
REMOVE AIR INTAKE HO
Next: !p807, !f808
BOILER ON/OFF SWITCH OFF
Next: !p811, !f812
ATTACH F.G.A UNIT TO FAN PRESSURE TEST POINT
Next: p815, f816
REMOVE THE FRONT COVER FROM THE HEAT EXCHANGER
Next: p819, !f820
REMOVE AIR INTAKE HO
Next: !p821, !f822
REMOVE THE BURNER AS
Next: !p825, ?827, ?829
BOILER ON/OFF SWITCH OFF
Next: p835, f1346
REMOVE THE FLAME SEN
Next: !p845, !f846
BOILER ON/OFF SWITCH OFF
DISCONNECT FAN CONNECTOR FROM THE PCB
Next: p853, !f852
REMOVE AIR INTAKE HO
Next: !p856, !f883
BOILER ON/OFF SWITCH
Next: p860, ?863, ?865
REMOVE AIR INTAKE HO
Next: !p872, !f882
REMOVE AIR INTAKE HO
Next: !p875, !f881
REMOVE AIR INTAKE HO
Next: !p878, !f880
BOILER ON/OFF SWITCH OFF
DISCONNECT FAN CONNECTOR FROM THE PCB
Next: p919, !f920
ON/OFF SWITCH OFF
Next: p921, !f922
REMOVE AIR INTAKE HO
Next: !p952, !f953
REMOVE AIR INTAKE HO
Next: !p956, !f957
REMOVE AIR INTAKE HO
Next: !p960, !f961
REMOVE RED LEADS FROM THE FLUE TEMPERATURE THERMOSTAT
Next: !p984, !f985
{GAINPCBACS}
Next: p1028, !f994
System Information
- Total Tests: 549
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control