Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Set selector switch to ch/dhw
Dhw temperature control to max
Measure temp across cold mains inlet and dhw outlet using
FGA temperature clamps, as close to the boiler as possible
Dhw temperature control to max
Measure temp across cold mains inlet and dhw outlet using
FGA temperature clamps, as close to the boiler as possible
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow boiler to ignite and run on DHW
With a flow rate at the tap of:
Compact / Sabre 24: 9.8 litres/min
Compact / Sabre 28: 11.5 litres/min
Is there a temperature rise of approximately 35° C and is operation satisfactory?
With a flow rate at the tap of:
Compact / Sabre 24: 9.8 litres/min
Compact / Sabre 28: 11.5 litres/min
Is there a temperature rise of approximately 35° C and is operation satisfactory?