Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
DHW Demand
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between connector X1 and the neutral at the incoming mains terminal strip as the flame ignites.
Expect the voltage to drop from 160v down to approximately 130v when the flame lights.
Note:
It may be necessary to reset the appliance during this test.
Click Here for Guidance on Resetting the Appliance
Expect the voltage to drop from 160v down to approximately 130v when the flame lights.
Note:
It may be necessary to reset the appliance during this test.
Click Here for Guidance on Resetting the Appliance

Isolate as per TOPs P4
and refit as necessary