Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector marked X36
Measurement:
Test 1:
Measure the resistance between the Black and Green wires at the disconnected connector.
Expect approximately 85 ohms.
Test 2:
Measure the resistance between the Black Wire at the disconnected connector and Earth.
Expect Open Circuit.
Test 3:
Measure the resistance between the Green Wire at the disconnected connector and Earth.
Expect Open Circuit.
Measure the resistance between the Black and Green wires at the disconnected connector.
Expect approximately 85 ohms.
Test 2:
Measure the resistance between the Black Wire at the disconnected connector and Earth.
Expect Open Circuit.
Test 3:
Measure the resistance between the Green Wire at the disconnected connector and Earth.
Expect Open Circuit.

Isolate as per TOPs P4
and refit as necessary