Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
DHW Demand
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With connector X15 attached to the PCB measure the voltage between the Brown wire and the neutral at the incoming mains terminal strip, when the appliance reaches the sparking stage of its ignition cycle after approximately 12 seconds.
Expect approximately 24V DC.
Note:
It is difficult to test the voltage on the connector itself, it is recommended the test is carried out on the small round metal test point on the PCB leading to the connector. It may be necessary to reset the appliance during this test.
For guidance on Resetting the appliance click here